46
Operating Instructions
|
airLPT216
Version 1.2
|
Dated: 07.03.2017
After the test period has expired the display
(5)
shows the following data:
•
average test pressure [Pa]
•
average volume flow, i.e. leakage rate [l/s]
•
maximum permitted volume flow (leakage rate) as
per class and surface area [l/s]
•
Test passed (ok) or failed (not ok)
After ending the test the buttons have the following
function:
F1 - MAIN
Back to Main menu
F3 - PRINT
Printout by means of record printer
(12)
.
If the button is pressed again the measured values
and the test result are printed out.
The record can be printed out from this
menu as often as required.
If the USB stick supplied is in the corresponding drive
(6)
, the record printout is saved on the USB stick as
a text file at the same time. The file name is made
up of the letters LPT and the 5-digit test number, e.g.
“LPT00123.TXT”. The date and time when the file was
created are saved and are visible, for example, if the
files are listed in WINDOWS Explorer. This file is only
written on the USB stick once, regardless of how of-
ten the paper copy of the record is printed.
OPERATION
TEST PRESS.
197 Pa
ACT 0.29 MAX
5.58
TEST PASSED!
[MAIN]
[PRINT]
F1
F2
F3
TEST PRESS.
1000 Pa
ACT 0.53 MAX
0.80
TEST PASSED!
[MAIN | BACK | PRINT]
F1
F2
F3
TEST PRESS.
193 Pa
ACT 6.59 MAX
5.50
TEST FAILED!
[MAIN]
[PRINT]
F1
F2
F3
K