60
Operating Instructions
|
airLPT216
Version 1.2
|
Dated: 07.03.2017
TROUbLEshOOTING
Troubleshooting
Fault
Possible cause
Action
Device does not work
Power cable not connected
Connect power cable (open side flap on the
right)
Device not switched on
Switch on device
Device fuse defective
Check device fuse, replace if necessary
Printer does not print
Paper roll empty
Insert new paper roll
Roll cover not closed
Close roll cover
Check backup battery
WATCH BATT. ALMOST FLAT!
Backup battery almost flat
Switch off device and hand it in to the service
department
Check program memory
PROGRAM MEMORY ERROR
Internal error
Switch off device and hand it in to the service
department
Check parameter memory
SETUP MEMORY ERROR
Internal error
Switch off device and hand it in to the service
department
USB drive error
USB drive error or defective USB
stick
Replace USB stick; device can continue to be
used; however, without option of saving data
on USB stick, hand in device to the service
department
Button test
BUTTON ERROR
Internal error
Gerät ausschalten und zum Service geben
Volume flow sensor test
VOLUME FLOW SENSOR
Internal error
Switch off device and hand it in to the service
department
Pressure sensor test
PRESSURE SENSOR ERROR
Switch off device and hand it in to the service
department
Fan motor test
FAN MOTOR ERROR
Switch off device
Remove the air hose and pressure measure-
ment hose from the device. Switch on device
and test again. If the error persists the device
must be handed in to the service department.
Note:
Please contact the manufacturer in case of operating faults or errors, which you cannot correct your-
self using these operating instructions.