AirKing DL4S Important Instructions Manual Download Page 5

www.airkinglimited.com

6727902 Rev. D 10-16

5 of 12

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Fan does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Connector plug from motor is not plugged in.  1b.  Turn off power to unit. Remove Grill and plug motor into receptacle

     

 

 

 

in housing. Restore power to unit.

     

1c.  Wiring is not connected properly. 

1c.  Turn off power to unit. Check that all wires are connected.

     

1d 

Motor has stopped operating. 

1d.  Replace motor.

  2.  Fan is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting. The most common are bird

     

 

 

 

nests in the roof cap or wall cap where the fan exhausts to the outside.

  3.  Fan is operating louder than normal 

3a.  Motor is loose. 

3a.  Turn off power to unit. Remove grill and check that all screws are fully

     

 

 

 

tightened. Restore power to unit.

     

3b.  Fan blade is hitting housing of unit. 

3b.  Call your dealer for service.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

LIMITED WARRANTY

WHAT THIS WARRANTY COVERS:

 This product is warranted against defects in workmanship and/or materials. 

HOW LONG THIS WARRANTY LASTS:

 This warranty extends only to the original purchaser of the product and lasts for five (5) years from the date of original purchase or until the original 

purchaser of the product sells or transfers the product, whichever first occurs. 

WHAT AIR KING WILL DO:

 During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the 

same or comparable model. 

WHAT THIS WARRANTY DOES NOT COVER:

 This warranty does not apply if the product was damaged or failed because of accident, improper handling, installation, or operation, shipping 

damage, abuse, misuse, unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay 

return shipping charges from Air King following warranty repairs or replacement 

ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE 

OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR 

KING’S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR 

REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLES. NOTWITHSTANDING ANYTHING TO THE CONTRARY, IN NO EVENT SHALL AIR KING’S LIABILITY UNDER ANY EX-

PRESS OR IMPLIED WARRANTY EXCEED THE PURCHASE PRICE OF THE PRODUCT AND ANY SUCH LIABILITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these exclusions or limitations 

may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state and province to province. Proof of purchase is required before a 

warranty claim will be accepted. 

CUSTOMER SERVICE:

Toll-Free (800) 465-7300

Our Customer Service team is available to assist you with product questions, service center locations, and replacement parts. They can be reached Monday through Friday, 8am-4pm Eastern. 

Please have your model number available, as well as the type and style (located on the label inside of your product). 

Please do not return product to place of purchase.

www.airkinglimited.com

PARTS FOR DISCONTINUED, OBSOLETE AND CERTAIN OTHER PRODUCTS MAY NOT BE AVAILABLE. DUE TO SAFETY REASONS, MANY ELECTRONIC COMPONENTS AND MOST 

HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT.

SECTION 10

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such as dishwashing liquid, 

and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. 

Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Completing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

CAUTION:

 ALLOW BULBS TO COOL BEFORE REPLACING.

3. 

Changing the Lamp:

 Disconnect power to the unit. Open the light lens on the grill by 

pushing into the lens and allowing in to spring open. Remove lamp by gently twisting the 

lamp base counterclockwise while applying outward pressure. Installation is the reverse of 

removal. Replace with Air King model AK8LED40 or a compatible GU24 8 watt LED lamp.

 

Night Light:

 Unscrew night light bulb from socket and replace with a 4 watt maximum 

type C7 (candelabra base) night light bulb.

Fuse

1. 

Follow the steps in 

SECTION 5

 

Wiring

 to gain access to the 

fuse holder located inside the wire compartment. To replace 

the fuse, squeeze the top an bottom of the fuse holder together 

while twisting the larger piece in a direction away from the 

tabs 

(Figure 13)

. Replace fuse only with 0.5 Amp, 250VAC, 5 x 

20mm, Fast Acting fuse. Reconnect the fuse holder by lining up 

the top an bottom section and squeeze together while twisting 

until they are locked in place. Carefully tuck back into the wire 

compartment and reinstall the wire compartment cover.

CALIFORNIA RESIDENTS ONLY:

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR 

CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.

WARNING:

 THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL 

[OR CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE 

REPRODUCTIVE TOXICITY.

Figure 13

Summary of Contents for DL4S

Page 1: ...bustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those pub...

Page 2: ...in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727902 Rev D 10 16 2 of 12 SECTION 4 Ducting NOTE...

Page 3: ...stripped 3b Wiring the Fan From where you have chosen to access the fan s junction box connect the white wire from the house to the white wire from the fan Connect the wire from the automatic positio...

Page 4: ...the button the number of times that corresponds with the amount of time you desire for instance 3 times sets the delay to 5 minutes see numbers in Step 1 The sensor will then flash the number of time...

Page 5: ...ITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or...

Page 6: ...Qty Description Replacement Part 7 1 Grill Assembly 5S1250105 8 1 Wire Compartment Assembly 5S1250105 Specific to Model DL4SG Qty Description Replacement Part 7 1 Grill Assembly 5S1250106 9 1 Wire Com...

Page 7: ...quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire...

Page 8: ...ez avoir 1 Grille 1 Ensemble de clapet attach 4 Supports de montage 1 Bride de montage 1 Ampoule de type LED 1 Feuillet d instructions s curit 2 Choisir un emplacement pour votre ventilateur Pour gara...

Page 9: ...endroit o vous avez choisi d acc der la bo te de jonction du ventilateur connectez le fil blanc de la maison au fil blanc du ventilateur Connectez le fil de la position automatique sur l interrupteur...

Page 10: ...ui correspond la quantit de temps que vous d sirez par exemple 3 fois d finit le d lai de 5 minutes voir les num ros l tape 1 Le capteur clignote alors le nombre de fois pour le nouveau param tre 3 fo...

Page 11: ...s de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous don...

Page 12: ...0105 Particularit s de mod le DL4SG Qt Description de pi ce de remplacement 7 1 Assembl e de Grille 5S1250106 9 1 Assembl e du compartiment du fil 5S1250108 Particularit s de mod le DL4SH Qt Descripti...

Reviews: