AirKing DL4S Important Instructions Manual Download Page 1

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6727902 Rev. D 10-16

1 of 12

Exhaust Fan with Light

Models:  DL4S, DL4SG, 

 

DL4SH, DL4SGH

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN 

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL 

INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock and 

injury to person, including the following:

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Use this unit only in the manner intended by the manufacturer.If you have 

questions, contact the manufacturer.

b)  Before servicing or cleaning the unit, switch power off at service 

panel and lock the service disconnecting means to prevent power 

from being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

WARNING:

 TO REDUCE THE RISK 

OF FIRE, ELECTRIC SHOCK AND INJURY TO 

PERSON, OBSERVE THE FOLLOWING: 

a)  Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-related construction.

b)  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 

back drafting. Follow the heating equipment manufacturer’s guideline 

and safety standards such as those published by the National Fire 

Protection Association (NFPA) and the American Society for Heating, 

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

c)  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

CAUTION:

 

FOR GENERAL VENTILATING USE ONLY. 

DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE 

MATERIALS AND VAPORS.

d)  Ducted fans must always be vented to the outdoors.
e)  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI (Ground 

Fault Circuit Interrupter) – protected branch circuit. 

f)  Do not install in a ceiling with thermal insulation value greater than 

R40.

g)  This unit must be grounded.
h)  To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

i)  Read all instructions before installing or using exhaust fan.

WARNING:

 TO REDUCE THE RISK OF FIRE, 

ELECTRIC SHOCK, DO NOT USE THIS FAN WITH 

ANY SOLID-STATE SPEED CONTROL DEVICE.

WARNING:

 DO NOT USE IN KITCHENS.

WARNING:

 

THE DUCTING FROM THIS FAN TO THE 

OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE 

AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST, 

STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE, 

AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN 

RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE 

ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH 

EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.

Summary of Contents for DL4S

Page 1: ...bustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those pub...

Page 2: ...in the previously cut hole so that it is flush with the finished ceiling Secure the ends of the rails to the joists Figure 1 www airkinglimited com 6727902 Rev D 10 16 2 of 12 SECTION 4 Ducting NOTE...

Page 3: ...stripped 3b Wiring the Fan From where you have chosen to access the fan s junction box connect the white wire from the house to the white wire from the fan Connect the wire from the automatic positio...

Page 4: ...the button the number of times that corresponds with the amount of time you desire for instance 3 times sets the delay to 5 minutes see numbers in Step 1 The sensor will then flash the number of time...

Page 5: ...ITY SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or...

Page 6: ...Qty Description Replacement Part 7 1 Grill Assembly 5S1250105 8 1 Wire Compartment Assembly 5S1250105 Specific to Model DL4SG Qty Description Replacement Part 7 1 Grill Assembly 5S1250106 9 1 Wire Com...

Page 7: ...quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi es par la National Fire...

Page 8: ...ez avoir 1 Grille 1 Ensemble de clapet attach 4 Supports de montage 1 Bride de montage 1 Ampoule de type LED 1 Feuillet d instructions s curit 2 Choisir un emplacement pour votre ventilateur Pour gara...

Page 9: ...endroit o vous avez choisi d acc der la bo te de jonction du ventilateur connectez le fil blanc de la maison au fil blanc du ventilateur Connectez le fil de la position automatique sur l interrupteur...

Page 10: ...ui correspond la quantit de temps que vous d sirez par exemple 3 fois d finit le d lai de 5 minutes voir les num ros l tape 1 Le capteur clignote alors le nombre de fois pour le nouveau param tre 3 fo...

Page 11: ...s de la p riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous don...

Page 12: ...0105 Particularit s de mod le DL4SG Qt Description de pi ce de remplacement 7 1 Assembl e de Grille 5S1250106 9 1 Assembl e du compartiment du fil 5S1250108 Particularit s de mod le DL4SH Qt Descripti...

Reviews: