6. ASSEMBLING INSTRUCTIONS
6.9 Installation of the Flue Terminal
Drill a hole on the wall in diametwr of 105 mm. The hole must be inclined towards the appliance at an angle of 3o.
If the flue terminal is installed to the side wall, check the levelling of the flue turret center and template hole center.
Please, see the figure below.
Draw a circle at the center point of the flue gas outlet in diameter of 105 mm.
Drill the wall according to the marked circle. The hole must be inclined towards the appliance
at an angle of 3
o
.
6.10 Connection of the Flue Extensions
The total length of the flue terminal is determined according to the distance between the place where the combi boiler
is installed and the exhaust gas terminal end. The extensions and use of the flow limiting part is determined according
to this distance. Please, see the figure below.
Extend the Standard flue terminal out of the hole.
Install the flue finishing kits.
Install the bend to the gas outlet of the combi boiler.
Install the extensions with bends and standart extension ducts.
Adjust the length of the extensions correctly
Flue terminal installation template
3°
6.11 Important Points During Installation of the Flue Terminal
The exhaust ducts must be sealed. During the installation of the bends be sure that the inner duct is installed correctly,
the exhaust duct is installed to the flue terminal outlet and all the connections are sealed perfectly.
Use the original flue terminal, bend and extensions. See the table for the bends and the total length of the flue terminal.
The total length must not be longer than permitted.
Standart connection
Extension connection