5.
System Preparation
Chapter 5
System Preparation
61
AirDog Calibration
AirDog Magnetometer (Mag) Calibration
5.6.2
5.6.2.1
Please note that all AirDog sensors have been factory-calibrated.
Accelerometer and Gyroscope sensors should be recalibrated ONLY if
AirLeash displays such warning message.
Magnetometer calibration shouldn’t be done unless there is a
physical sensor replacement or the AirLeash displays such warning
message.
The magnetometer is very sensitive to magnetic interferences and
its calibration requires an interference-free environment. Stay away
from metal and concrete structures such as buildings, parking or any
metal structures. Do not wear gloves or rings with magnets or other
ferromagnetic metals while performing the calibration steps.
AirDog is only meant to work outdoors and indoor calibration will
lead to faulty measurements.
Magnetometer calibration process:
1. Insert the battery in the unfolded AirDog.
2. Long press (3sec.) on Power/OK button to power
AirLeash on.
3. Short press on the Menu button to enter the Menu.
4. Navigate through the Menu with arrows until you
see the Settings icon on the LCD screen.
5. Short press on Power/OK to enter Settings .
6. Navigate through Settings with arrows until you see the
Calibration icon on the LCD screen.