INSTALLATION INSTRUCTIONS

1.1 CONTROLLER LOCATION

The AirCycler® g2 controller can be installed near the thermostat or out of view on/near the air handler unit. 

Warning: Before installing the AirCycler®, turn off all power to the furnace. There may be more than one power to disconnect. 

Electrical shock can cause injury or death.

1.2 INSTALLING THE AirCycler®

On power up, all icons will be illuminated for 3 seconds.  

There  are  two  set  up  methods:  Calculated  Time  and  Calculated 

Flow.  Calculated  Flow  is  used  primarily  with  the  optional 

FanConnect™ bath fan/light switch.

OPERATING MODE DISPLAY

Normal display will show the percentage of the current ventilation cycle (hour) that is complete.

If the central fan is on, the FAN and ON icons will show. 

If the exhaust (bath) fan is on, the EXH icon will show. 

If the outside fresh air damper is open the OA icon will 

show.

If the EXH fan is running its set delay time after the 

FanConnect

 has been turned off, the delay time 

countdown as well as the MIN and EXH icons will show. 

The ON icon is only shown when the AirCycler

®

 g2 has 

forced the central fan on. 

Pressing the MODE button at any time during normal 

operation will go to setting the current time of day.

THE EXHAUST 

FAN IS ON

THE THERMOSTAT 

HAS TURNED ON 

THE CENTRAL FAN

THE AIRCYCLER® G2 

HAS FORCED THE FAN 

THE DAMPER 

IS OPEN

PERCENTAGE OF 

VENTILATION COMPLETE

1.0 G2 OPERATION & DISPLAY

UP ARROW

Use as directed during set up.

During Normal Operation, use to view 

current status

MODE BUTTOM

Use as directed during set up.

During Normal Operation, use to cycle

through current time of day

DOWN ARROW

Use as directed during set up.

During Normal Operation, use to view

current settings

Summary of Contents for g2

Page 1: ...AirCycler g2 g2 k Installation User s Guide VENTILATION MADE BREEZY a breeze to install a breeze to use Ventilation Products...

Page 2: ...ectrical codes during installation All wiring must conform to local and national electrical codes Improper wiring or installation may result in personal injury or product and property damage INSTALLAT...

Page 3: ...e building mechanical ventilation rate The bathroom exhaust fan should have a sound rating of 1 0 sone or less This recommendation is a requirement if the home is certified as an ENERGY STAR V3 home i...

Page 4: ...rough in either direction although it is recommended to install with the crimped end as the outlet Use care to avoid distorting the damper housing and provide adequate support CHOOSE A FRESH AIR LOCAT...

Page 5: ...N icons will show If the exhaust bath fan is on the EXH icon will show If the outside fresh air damper is open the OA icon will show If the EXH fan is running its set delay time after the FanConnect h...

Page 6: ...f Factory default is 10 minutes Press MODE to save all settings and return to normal operation 2 1 5 CALCULATED FLOW SETUP IS COMPLETE Set up is complete The AirCycler g2 will now return to normal ope...

Page 7: ...enter YES the AirCycler g2 will prompt you to enter the hour you would like the ventilation to begin and the hour you want it to end followed by the current time Set the hour you want the ventilation...

Page 8: ...been open with the central fan running 3 1 3 EXHAUST RUN TIME This shows the elapsed run time of the exhaust fan for this time period 3 1 4 EXHAUST DELAY TIME This shows the exhaust delay time set 3...

Page 9: ...RRENT TIME By pressing the MODE key you will cycle through current time of day and will be able to change it if needed APPENDIX A ASHRAE 62 2 REFERENCE CHART CFM Required 7 5 CFM N 1 A 0 01 N No of Be...

Page 10: ...the motorized damper does not cycle Confirm 1 The AirCycler g2 is providing a 24 VAC signal to the motorized damper 2 The 24 VAC motorized damper is operational by powering directly with a 24 VAC sign...