INTRODUCTION

If the AirCycler® g1 was installed in your home as a ventilation controller, turning off or otherwise disabling the 

controller could result in under ventilating your home and could adversely impact indoor air quality.

In the past, homes depended on natural leaks for ventilation. Today, energy efficient homes are built to reduce natural 

ventilation and leaks.  Inadequate ventilation can cause indoor air pollutants to rise to harmful levels.  Indoor air quality 

is typically 5 to 10 times more polluted than outside air. Controlled ventilation systems like the AirCycler® g1 provide 

adequate air flow to the home without compromising its efficiency.

The AirCycler® g1 is integrated with the home’s HVAC system. When the home’s furnace fan is turned on by the 

thermostat to provide heating or cooling, the AirCycler® g1 controller opens a motorized damper to let in a measured 

amount of fresh air. The fresh air is filtered by the return plenum filter and is then distributed uniformly throughout 

the home through the existing ductwork. Once the ventilation requirements are met, the damper is closed to prevent 

over-ventilation. If there are not enough heating or cooling calls to meet ventilation requirements for the hour the 

AirCycler® g1 will turn on the furnace fan and open the motorized damper until requirements have been met.

SAFETY CONSIDERATIONS

Read and follow manufacturer’s instructions carefully. Follow all local electrical codes during installation. All wiring 

must conform to local and national electrical codes.  Improper wiring or installation may result in personal injury or 

product and property damage.

INSTALLATION CONSIDERATIONS

The AirCycler® g1 requires 24VAC (R and C terminals) to be connected for proper operation.  The controller will not 

operate without these two connections.

The  wires  (R, C, &  W )  from  the  air  handler  to  the thermostat can run parallel with the wiring from the AirCycler® 

g1 to the air handler. The fan wire (G) must be interrupted by the AirCycler® g1.  Some thermostats do not require a 

common (C) connection.  The AirCycler® g1 requires this for power, which must be wired to the furnace.

BATTERY (MODEL CR1220)

The AirCycler® g1 is equipped with a real time battery backed-up clock for use with the Operation Hours setting ONLY. 

If not setting the hours of operation, the included battery is not required. All other settings are saved in nonvolatile 

memory.

RECORD ALL SETTINGS ON THE INSTALL STICKER PROVIDED. LIMITED 

WARRANTY WILL BE VOID IF THE STICKER IS NOT PRESENT.

Summary of Contents for g1

Page 1: ...AirCycler g1 Installation User s Guide VENTILATION MADE BREEZY a breeze to install a breeze to use Ventilation Products ...

Page 2: ...here are not enough heating or cooling calls to meet ventilation requirements for the hour the AirCycler g1 will turn on the furnace fan and open the motorized damper until requirements have been met SAFETY CONSIDERATIONS Read and follow manufacturer s instructions carefully Follow all local electrical codes during installation All wiring must conform to local and national electrical codes Imprope...

Page 3: ...ires the central blower used with the AirCycler g1 to use an electronically commutated motor WIRING DIAGRAM Y R W G Y R C W G White OPTIONAL DAMPER Red Blue THERMOSTAT AirCycler g1 AIR HANDLER KEY R 24VAC Power C Common Gt Fan From Thermostat Gf Fan To Furnace V Vent Vnc Normal Closed Vent ...

Page 4: ...if mounted horizontally Air may flow through in either direction although it is recommended to install with the crimped end as the outlet Use care to avoid distorting the damper housing and provide adequate support Upon system start up be sure to set damper power switch to UP or AUTOMATIC position CHOOSE A FRESH AIR LOCATION ASHRAE recommends that the fresh air intake be located at least 10 ft fro...

Page 5: ...t up the AirCycler g1 based on Calculated Time press and hold the DOWN arrow for 10 seconds OPERATING MODE DISPLAY When the AirCycler is in Normal Operation the display will show the percentage of ventilation complete for the current hour If the outside fresh air damper is open the OA icon will show If the thermostat is calling for heat or cool the FAN icon will be illuminated without the ON icon ...

Page 6: ...ation press the UP arrow for yes YS Press MODE to select yes The AirCycler g1 will prompt you to enter the hour you would like the ventilation to begin and the hour you want it to end followed by the current time Set the hour you want ventilation to START Press MODE to advance to the next setting Set the hour you want the ventilation to STOP Press MODE to advance to next setting 2 4 1 SETTING CURR...

Page 7: ...ING OPERATION HOURS If the user does not want the ventilation system to run throughout the day you can set ON time and OFF time Factory default is NO If you are not setting an ON and OFF time press MODE and continue to section 3 4 If you want to set hours of operation press the UP arrow for yes YS Press MODE to select yes The AirCycler g1 will prompt you to enter the hour you would like the ventil...

Page 8: ...ns will show Required CFM set Measured outside air CFM If operating time is enabled Operating Time ON Operating Time OFF For Calculated Time mode the screens will show Outside air time in minutes If operating time is enabled Operating Time ON Operating Time OFF 5 0 SET CURRENT TIME By pressing the MODE key you will cycle through current time of day and will be able to change it if needed See secti...

Page 9: ...CFM N 1 A 0 01 N No of Bedrooms A Square Footage Square Footage No of Bedrooms SOFTWARE VERSION To determine the software version used in your controller press and hold the DOWN arrow for 15 seconds from normal operation The software revision number will be displayed on the screen ...

Page 10: ... fan operates with a fan only signal from the thermostat 5 The furnace is providing 24 VAC to the AirCycler g1 6 Verify wiring conforms to wiring diagram 7 Make sure cover is firmly seated on the base Problem AirCycler g1 turns furnace fan on and off but the motorized damper does not cycle Confirm 1 The AirCycler g1 is providing a 24 VAC signal to the motorized damper 2 The 24 VAC motorized damper ...

Reviews: