OTHER FEATURES / INDICATIONS
4) This humidifier has a check filter reminder timed to appear after 720
hours of operation. When the Check Filter (CF) message is
displayed, disconnect the power cord and check the condition of the
filter. The CF function is reset after plugging the unit back in.
5) When the unit is out of water, a flashing F will display on the display panel.
AUTO DRYOUT
At this time the unit will automatically switch into
AUTO DRY OUT
MODE
and continue to run on the lowest speed until the filter is
completely dry. The fan will shut off leaving you with a dry humidifier
that is less prone to mold and mildew.
If
AUTO DRY OUT MODE
is not desired, refill the humidifier with
water and the fan will return to the set speed.
WICK REPLACEMENT
The EP9 / EP9R Series uses the 1043 Super Wick. Always use the original
AIRCARE/ Essick brand wick to maintain your unit and maintain your warranty.
1) First, remove any items on top of the pedestal and remove the natural stone
tile and place in a safe location.
2) Lift chassis up off the base to reveal the wick, wick retainer and float.
3) Remove the wick and retainer assembly. Separate the two-part wick retainer.
4) Remove the old wick, drain excess water and discard.
5) Place new 1043 wick into front side of the wick retainer and snap the larger,
back section into place.
6) Then place the wick assembly into the base, aligning it with the built-in guides.
7) Replace the chassis on top of the base being careful to note the front of the
unit and not damage the float when repositioning the chassis.
7