Plug in your unit and remove the 

plastic tab from the remote. Press 

the power button   on either the unit or the 

remote.  

Set your desired output level by 

pressing the power button on the 

unit, or the mist output button   on the 

remote. Your MESA has three output levels 

that are displayed on the power button by 

green (low), yellow (medium), and red (high). 

Switch between cool and warm mist 

by pressing the 

+

 button on the unit 

or the mist temperature button   on the 

remote. It will take the MESA a few minutes 

to reach the warm mist temperature. The 

+

 button will glow red when the MESA is in 

warm mode.

Turn on the nightlight by pressing the 

nightlight button on the unit   or on 

the remote  .

That’s it! Your MESA is ready to use.

6

7

8

9

Regular cleaning is important for preventing 

mold, mildew, and other bacterial growth in your 

humidifier.  It also keeps your MESA working its 

best.

NOTE

: Do not allow any liquid to get into the air intake while you 

are cleaning your MESA.

1. 

Let the unit run until it’s empty, then turn it off and unplug it. 

2.  Remove the lid and the essential oil tray and pad. Set these aside.
3.  Remove the tank and your demineralization cartridge. Throw your 

cartridge away if it is time to replace it. Otherwise, put it in a sink 

while you finish cleaning your MESA.

4.  Pour out any remaining water from the tank and the base. 
5.  Fill the tank a little more than half-full with water and add 2 

tablespoons of white vinegar. Pour a little of this vinegar-water 

mixture into the base.

6.  Put the water cap back on, shake the tank, then let sit for 20 

minutes.

7.  With the mixture in the base, use a soft cloth to clean the inside of 

the base. Gently scrub the oscillator (the dark ring in the basin). Let 

sit for 20 minutes.

8.  After 20 minutes, empty the water tank and base. 
9.  Dampen a sponge with white vinegar and wipe down the base, 

tank, essential oil tray, and lid. Rinse everything thoroughly. 

10.  Wipe everything dry and replace the demineralization cartridge, if 

needed. Then reassemble.

When storing your MESA

, discard the used demineralization 

cartridge and clean the unit as described above. Dry the unit 

thoroughly, and store in a temperature-regulated area. Do not 

install a new demineralization cartridge until you are ready to use 

your humidifier again again.

HOW TO CLEAN YOUR MESA

AIR INTAKE

5

6

Summary of Contents for be11061

Page 1: ...Everything you need to know about your Read and save these instructions MESA ALL MU320DWAL MODELS 1B73376 8 2020...

Page 2: ...1B73115 h Demineralization cartridge DC1003PK i Owner s manual 1B73376 1 a b c d f g h i e LET S GET YOU UP AND RUNNING Prefer to see a video Watch the MESA set up at aircareproducts com support SCAN...

Page 3: ...times notice with ultrasonic humidifiers We recommend replacing your cartridge every 60 90 days To do this simply remove the water tank take out the old cartridge then drop in a new one 3 2 4 5 Top vi...

Page 4: ...lid and the essential oil tray and pad Set these aside 3 Remove the tank and your demineralization cartridge Throw your cartridge away if it is time to replace it Otherwise put it in a sink while you...

Page 5: ...ence sont indiqu s la page 10 Le r glage de la brume froide est de 66 2 degr s et celui de la brume chaude est de 76 8 degr s La temp rature de la maison peut parfois influer sur cette valeur La pouss...

Page 6: ...15 h Cartouche de d min ralisation DC1003PK i Manuel du propri taire 1B73376 1 a b c d f g h i e IL EST TEMPS DE TE LANCER CAMERA Pr f rez vous voir une vid o Regardez l installation de MESA sur airca...

Page 7: ...ons de remplacer votre cartouche tous les 60 90 jours Pour ce faire il suffit d enlever le r servoir d eau de retirer l ancienne cartouche puis d en d poser une nouvelle 3 2 4 5 Top view of tank DC100...

Page 8: ...z le 2 Retirez le couvercle le plateau huiles essentielles ainsi que la plaquette aux huiles essentielles Mettez les de c t 3 Retirez le r servoir et la cartouche de d min ralisation Jetez la m che s...

Page 9: ...dad Puede escribirlo aqu para futuras consultas _ _ _ _ _ _ _ _ _ _ Su MESA dejar de funcionar y el bot n de encendido parpadear de color rojo cuando se acabe el agua El MESA es un humidificador de ro...

Page 10: ...oto incluye una bater a CR2025 1B73115 h Cartucho de desmineralizaci n DC1003PK i Manual del usuario 1B73376 1 a b c d f g h i e PREP RESE PARA HACER FUNCIONAR EL APARATO CAMERA Prefiere ver un video...

Page 11: ...as notan en los humidificadores ultras nicos Le recomendamos que reemplace su cartucho cada 60 90 d as Para hacerlo solo quite el tanque de agua extraiga el cartucho viejo y luego introduzca uno nuevo...

Page 12: ...ench fela 2 Quite la tapa y la bandeja y la almohadilla de aceites esenciales Col quelas a un costado 3 Quite el tanque y el cartucho de desmineralizaci n Deseche el cartucho si es hora de reemplazarl...

Page 13: ...t hot Yes Your MESA s parts and their part numbers are listed on page 2 The cool mist setting is 66 2 degrees and the warm mist setting is 76 8 degrees Household temperatures can sometimes affect this...

Reviews: