11. Trouble shooting
Machine will not start.
Cause
Check
Repair
Poor or no air
supply
Check if air pressure reading at
gauge is at least 1.5 bar (20 psi)
Resolve air supply problem
Defective trigger
Check if control hoses are not bent.
Disconnect the blue hose at the
machine and check if pressurised air
is released.