9. Troubleshooting
9.1 Displaying Special Statuses
The corresponding zone display alternates between two characters depending on the status.
(1)
For T1, T2, T3, T4, T5 and T6 values see the corresponding drawing.
9.2 Errors/Alarms
9.2.1 Appliance Errors
Appliance errors are the errors which generate the deactivation of the whole hob.
When an appliance error is detected, all heaters are switched off, a beep sounds (only if one or more zones
are active) and all displays show a
‘
F
’
letter and the error code alternately.
While in error status all the zone keys are not operative.
Except EEPROM and microcontroller errors, all errors are recoverable. That is, when the cause of the error
disappears all displays are deactivated and the hob returns to normal operation.
Special status
(Visualization
Priority Order)
Start
conditions
End
Conditions
Action
Zone
Status
Zone
Display
Front
Zone
Display
back
Power increment not
allowed (only for ECO
models)
Asked hob
power > Hob
ECO power limit
2 sec
Power
increment not
allowed
On/Off
‘
r
’
Zone without suitable
pan or without pan
(2)
No pan or not
suitable pan
over the zone
Suitable pan
over the zone
After 1 minute
zone off
On
‘
Power
’
‘
U
’
(2)
Induction zone over
temperature
COIL
TEMPERATURE
> T1 (1)
COIL
TEMPERATURE
> T1 (1)
No power is
delivered to
the zone
Off
‘ ‘
or
‘
H
’
‘
C
’
On
‘
Power
’
Induction generator
over temperature
HEATSINK
TEMPERATURE
> T3 (1)
HEATSINK
TEMPERATURE
> T4 (1)
No power is
delivered to
the zone
Off
‘ ‘
or
‘
H
’
‘
c
’
On
‘
Power
’
Hot glass over a zone
(residual heat)
COIL
TEMPERATURE
> T5 (1)
COIL
TEMPERATURE
> T6 (1)
-
-
-
-
-
-
-
-
Off
‘
H
’
Summary of Contents for Diamond 60