22
9.2.2 Zone Errors
Zone errors are the errors which generate the switch off of one or more zones. When a zone error is
detected, the involved zones are switched off, a beep sounds (only if one or more zones are active) and the
display corresponding to these zones show a
‘
F
’
letter and the error code alternately.
While in error status the keys of the corresponding zones are not operative. All errors are recoverable. That
is, when the cause of the error disappears, the corresponding displays are deactivated and the zones return
to normal operation.
Appliance Errors
Error (Visualisation Priority
Order)
Error Recovery
Action
All Zone Displays
(front 0.5 sec/back 0.5 sec)
Microcontroller fault
-
-
-
-
-
-
-
-
-
App. off
F0
On/Off key emitter fault
When the fault disappears
App. off
FA
On/Off key receiver fault
When the fault disappears
App. off
FC
User interface temperature
sensor short
-
circuit
When the fault disappears
App. off
FE
User interface temperature
sensor open
-
circuit
When the fault disappears
App. off
Ft
User interface
overtemperature
When user interface
temperature < 90°C
App. off
Fc
EEPROM fault
-
-
-
-
-
-
-
-
-
App. off
FH
Microcontroller A/D converter
multiplexer fault
When the fault disappears
App. off
FJ
Ambient Light fault
When satisfactory ambient
lighting is detected
App. off
FL
Microcontroller A/D converter
conversion fault
When the fault disappears
App. off
FU
Summary of Contents for Diamond 60