Page 1: ...Operating instructions DFPQSL Range hood ...

Page 2: ...ructions went to press The right to make tech nical modifications for the purpose of the further development of the appliance is reserved Validity The product family model number corresponds to the first alphanumerics on the identification plate These operating instructions apply to Type Product family Size system Motor housing no DFPQSL9 61007 90 H4 2608 extraction standard H4 2606 recirculation ...

Page 3: ... Operating and display elements 11 4 Operating the appliance 12 4 1 Using for the first time 12 4 2 Operation 14 4 3 Intensive level 15 4 4 After running time 15 4 5 Illumination 15 4 6 Saturation indicator 16 4 7 Wipe protection 16 5 Care and maintenance 17 5 1 Cleaning the housing 17 5 2 Cleaning the grease filters and combi filters 18 5 3 Replacing the activated charcoal filters 20 5 4 Replacin...

Page 4: ...ecautions can result in injury or in damage to the appliance or fittings Information and precautions that should be observed Information on disposal Information about the operating instructions Indicates step by step instructions Describes how the appliance reacts to the steps taken Indicates a list 4 ...

Page 5: ... for disconnecting from the mains with a con tact opening on each pole complying with the conditions of overvoltage category III for full isolation an isolating device must be incorporated into the permanently installed electrical installation in accordance with the installation regulations If the mains cable of this appliance is damaged it must be re placed by the manufacturer or its Customer Ser...

Page 6: ...s accompany the appliance together with the instructions on installation In this way the new owner can inform themselves about how to use the ap pliance correctly and read the pertinent safety precautions 1 5 Children in the home Packaging material e g plastic film and polystyrene can be dangerous for children Danger of suffocation Keep packaging material away from chil dren The appliance is desig...

Page 7: ... a disturbing underpressure in the kitchen and to achieve op timal air extraction Avoid a cross current of air which could blow the cooking vapours over the cooking area If other appliances fuelled by gas or other fuels are being used at the same time ensure that there is a sufficient supply of fresh air This does not apply to air recirculation appliances If other firing systems are being used at ...

Page 8: ...ave the appliance disconnected from the mains by an electrician Then cut the mains cable off flush with the appliance Disposal The old appliance should not be discarded as worthless rubbish If dis posed of correctly the raw materials can be recovered for recycling The symbol on the identification plate warns that the appliance may not be disposed of in normal household waste The appliance must be ...

Page 9: ...are filtered through the metal grease filters and then passed through an activated charcoal filter The filtered air is then circulated back into the room 3 4 Equipment 1 extractor fan with 4 power levels 1 low 2 medium 3 high and intensive level Power levels 1 3 are suitable for continuous operation The intensive level is used for short bursts of intensive extraction of cooking fumes and smells e ...

Page 10: ...3 Your appliance 3 5 Construction 1 2 4 3 1 Operating elements 2 Combi filter 3 Grease filter 4 Illumination 10 ...

Page 11: ...ection Illuminated Wipe protection activated Timer Illuminated Timer activated Saturation indicator for grease filters Flashing Clean grease filters Saturation indicator for activated charcoal filters Flashing Replace activated charcoal filters Depending on the model and features the specification of the appli ance may partly differ in individual details from the standard specifica tion described ...

Page 12: ...xtraction model the saturation in dicator for the activated charcoal filter must be deactivated Amount of activated charcoal used Remove the grease filters and combi filters see Cleaning the grease filter and combi filter see page 18 For the length of the motor hous ing see on the inside see arrow Short motor housing 2 5 kg activated charcoal Long motor housing 5 kg activated charcoal Activating a...

Page 13: ...counter for the activated charcoal filters must be deactivated Deactivating the saturation indicator for the activated charcoal filters Switch the appliance off Depress the button for 3 seconds The and displays flash Depress the button again for 3 seconds The and displays go out The range hood is now set up as an extraction model Checking the settings Switch off the appliance Depress the button fo...

Page 14: ...and then pull out again within 2 seconds The next higher power level is selected This procedure can be repeated up to the intensive level If this is repeated again the appliance switches back to power level 1 We recommend switching the appliance on at power level 1 some 5 minutes before cooking Use a low power level for normal cooking smells and a higher power level for very strong cooking fumes a...

Page 15: ...power level 4 4 After running time Switch the appliance on Press the button to select the desired power level Press the button to activate the after running time function With the after running time function the appliance keeps running according to the following table and then switches off automatically Button After running time 20 minutes 15 minutes 10 minutes Flashing 5 minutes 4 5 Illumination ...

Page 16: ...ers The display illuminates after 1 200 700 or 400 operating hours depending on the setting selected The saturation level has been reached and the activ ated charcoal filters must be replaced 4 7 Wipe protection This function prevents the range hood from being switched on accidentally while cleaning The range hood must be switched off Depress the button for 5 seconds illuminates in the display The...

Page 17: ...g pads steel wool etc for cleaning as they can damage the surface Remove the screw fuse or switch off the circuit breaker Cleaning the outside inside Clean the outside using a slightly damp cloth and detergent if necessary and wipe dry Grease and condensate water can build up on the inside next to the metal grease filters Clean using a slightly damp cloth and detergent if necessary and wipe dry 17...

Page 18: ...ke both grease filters out of the holder 1 2 3 4 55 cm 60 cm model Carefully take the grease filter 1 down and out Fold down the grip 4 on the combi filter 3 Carefully pull the combi filter 3 down and out of the holder Do not damage the grease filter Cleaning Clean the grease filters and combi filters on their own in an upright position in a dishwasher Set the dishwasher to an intensive or heavy s...

Page 19: ...m model 55 cm 60 cm model Insert the grease filters into the holder Insert the holder into the slots at the back and raise and engage in posi tion at the front Insert the grease filters into the slots at the side Fold down the grip Swing the grease filters up and engage in position With the appliance switched off depress the button for 5 seconds to re set the saturation indicator The button stops ...

Page 20: ... is in op eration or a power level is activated Spent activated charcoal filters can be disposed of in the household waste The activated charcoal filters have been developed especially for this appli ance and can only be ordered from V ZUG Ltd s Customer Services The activated charcoal filter consists of Activated charcoal filter A Activated charcoal filter B Removing the activated charcoal filter...

Page 21: ...n the 6 screws in the front cover D and remove the cover D Lift the activated charcoal filters A and B one after the other from the front and pull out B A 1 2 3 4 Detach the activated charcoal filter A from the metal holder E E A 21 ...

Page 22: ...oal filter A to the metal holder E Position metal holder E on topmost activated charcoal filter B The activated charcoal filters A are located in the side panels Press the metal cover C upwards and engage in position Screw on front cover D If appropriate put back flue casing Connect the appliance to the mains power supply With the appliance switched off depress the button for 5 seconds to re set t...

Page 23: ...ion in the power supply Check the power supply LED is defective Inform Customer Services the appliance is not extracting enough air Possible cause Solution The metal grease filters are dirty Clean the metal grease filters Only for recirculation model The activated char coal filters are saturated Replace the activated charcoal filters Only for extraction model The fresh air intake is in sufficient ...

Page 24: ... appliance and exact description of the ac cessory or spare part when ordering parts Grease filter Grease filter holder for 90 cm hood width Combi filter Activated char coal filter When ordering the activated charcoal filter give the length of the motor hous ing 24 ...

Page 25: ...8 Technical data Electrical connection See identification plate Remove the metal grease filters The identification plate is located on the inside of the appliance 25 ...

Page 26: ...emoving 18 Saturation indicator 16 I Identification plate 25 Illumination 10 15 Intensive level 15 L LED Replacing 22 M Malfunction Illumination not working 23 Model number 2 N Notes 28 O Operating elements 10 11 Operating the appliance 12 P Packaging 8 Product family 2 Q Quick instructions 32 R Recirculation model 9 S Safety 8 Safety precautions Before using for the first time 5 Children in the h...

Page 27: ...9 Index V Validity 2 W Warranty extensions 31 What to do if The appliance is not extracting enough air 23 The illumination is not working 23 Wipe protection 16 27 ...

Page 28: ...28 10 Notes ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...e the serial number FN and appliance designation to complete the registration process This information can be found on the identification plate for your appliance My appliance information FN ___________________ Appliance _____________________ Always have this appliance information to hand when you contact V ZUG Thank you Remove the metal grease filter The identification plate is located on the ins...

Page 32: ...wer level 2 Power level 3 Flashing Intensive level Wipe protection Illuminated Wipe protection activated Timer Illuminated Timer activated Saturation indicator for grease filters Flashing Clean grease filters Saturation indicator for activated charcoal filters Flashing Replace activated charcoal filters V ZUG Ltd Industriestrasse 66 CH 6301 Zug info vzug com www vzug com J61007352 R03 ...

Reviews: