4  Technical data

Model

AS60

AS90

AS120

Number of compressor generators

2

3

4

Max Users @ 60% 

60

90

120

Max Simultaneous Users @ 100%

40

60

80

Operating Voltage

V

~

 480 VAC

Electrical frequency

Hz

60

60

60

Power consumption

hp / kW

15 / 11  

22�5 / 16�5  

30 / 22  

Current consumption (400 VAC / 480 VAC)

A

39 / 32

54 / 45

68 / 56

Branch circuit breaker (400 VAC / 480 VAC)

A

50 / 40

70 / 50

90 / 60

Minimum wire gauge of electrical
 supply line* (400 VAC / 480 VAC)

AWG

8 / 8

4 / 6

3 / 4

RPM

min

-1

1800

Circuit Breaker type

IP 20

Protection class

1

Duty cycle

%

100

Switch-on pressure (factory setting)

psi

(bar)

102 / 109

(7 / 7�5)

94 / 102 / 109 

(6�5 / 7 / 7�5)

87 / 94 / 102 / 109

(6 / 6�5 / 7 / 7�5)

Cut off pressure (factory setting)

psi

(bar)

109 / 116

(7�5 / 8)

102 / 109 / 116

(7 / 7�5 / 8)

94 / 102 / 109 / 116 

(6�5 / 7 / 7�5 / 8)

Safety valve settings

psi

(bar)

10

145

Tank volume

Gal / L

120 / 454

Delivery rate at 85 psi (6 bar)

100 psi (7 bar)

CFM / 

LPM

60 / 1,700    

56�6 / 1,600 

  90 / 2,550 

 84�8 / 2,400 

120  / 3,400 

113�1 /  3,200 

Noise levels at or 73 psi (5 bar) **
- without noise reducing hood

dB(A)

88

91

93

System Weight
- compressor module
- control module

lbs (kg)
lbs (kg)

505 (229)
700 (318)

835 (379)
700 (318)

1055 (479)

700 (318)

Shipping Weight
- compressor module
- control module

lbs (kg)
lbs (kg)

605 (275)
850 (386)

940 (425)
850 (386)

11505 (522)

850 (386)

Connections
- compressed air outlet
- condensate inch or mm

1 inch NPT internal thread

0�8"  / 20

Volume of condensate

�05 gallon or 200ml or per condensate drain cycle

depend on rel� Humidity and Temperature

Required room ventilation

CFM

530

742

989

Dimensions (H x W x D)
- compressor module

- compressor module and pallet

- control module

- control module and pallet

in�

(cm)

in�

(cm)

in�

(cm)

in�

(cm)

38x51x39  

(95x129x99)

44x55x43 

(110x138x109)

82x39x51 

(209x99x129)

93x43x55 

(235x109x138)

71x51x39 

(180x129x99)

75x55x43 

(195x138x109)

82x39x51 

(209x99x129)

93x43x55 

(235x109x138)

71x51x39 

(180x129x99)

(75x55x43) 

(195x138x109)

82x39x51 

(209x99x129)

93x43x55 

(235x109x138)

Total required space

in� 

(cm)

86x138x111 

(220x350x280)

86x138x111 

(220x350x28)

86x138x111 

(220x350x280)

*  The cross-section of the electric supply cable must be matched to the current consumption, length of supply line and 

local situations (see 10�3 Connection line dimensions) 

**  According to EN ISO 1680 Noise emissions; measured in a sound-proofed room� The values are average values with 

tolerances of approximately ±1�5 dB(A)� 

Summary of Contents for AirStar AS120

Page 1: ...Installation Operating Instructions AirStar Clinical Air Compressor AS60 AS90 AS120 AS60 400 AS90 400 and AS120 400...

Page 2: ......

Page 3: ...8 2 Module layout 12 8 3 Set up and secure modules 12 9 Installation 13 9 1 Connect the compressed air connection to the cyclone separator 13 9 2 Connect the pressure tank to the com pressed air supp...

Page 4: ...jury IMPORTANT Possible danger which could result in serious damage Further symbols The following symbols are used within this document and on the actual appliance Notes e g special instructions conce...

Page 5: ...xperience Every person operating the device must be trained in its handling Installation and repair and maintenance Installation resetting alterations adding of extensions and repairs must be carried...

Page 6: ...nd Operating Instructions AS60 400 Control module Compressor module with 2 compressor aggregates Boost transformer Connecting cables and hoses Mounting materials Installation and Operating Instruction...

Page 7: ...ule control module lbs kg lbs kg 505 229 700 318 835 379 700 318 1055 479 700 318 Shipping Weight compressor module control module lbs kg lbs kg 605 275 850 386 940 425 850 386 11505 522 850 386 Conne...

Page 8: ...ame of manufacturer Air Techniques Name of unit AirStar Clinical Air Compressor Models AS60 AS90 AS120 AS60 400 AS90 400 AS120 400 Control panel ConformstoUL508A theULStandardforConstruction Of Indust...

Page 9: ...d air which is used to operate dental units simulation stations phantom places and similar The display panel is used to configure the operation of the device monitor the operating status e g fault rep...

Page 10: ...ar 7 Control connection 8 Tank connection to air network 1 inch NPT 9 Condensate drain 10 Condensate separator drainage 11 Pressure sensor 12 Refrigerant dryer bypass valve 13 Refrigerant dryer valve...

Page 11: ...ggregatethenrunsincontinuousoperation The alternation of aggregates no longer takes place When no air is taken from the tank the pressure in the tank increases to 145 psi 10 bar and will be maintained...

Page 12: ...ation in purpose built rooms e g boiler room must be checked against building regulations beforehand Do not operate the units in damp or wet environments Clearly indicate that the room may only be ent...

Page 13: ...air supply net Connect the pressure tank to the supply network using a flexible compressed air hose on site connection 1 inch NPT external thread 9 3 Connect the condensate drain outlet to the waste w...

Page 14: ...e following information on connecting electrical lines is based on US and Canada standards Always observe the relevant national standards and local rules and regulations Diameter of the connections Th...

Page 15: ...ave been used The compressed air for the dew point measurement should be taken from the measuring connection point 1 1 11 Initial start up Wear ear protectors 11 1 Switching on compressed air station...

Page 16: ...e switch to Emergency Mode setting 2 The compressor aggregate then runs in continuous operation The red LED Fault shows 0 1 2 13 Decoupling a single compressor aggregate Where a single compressor aggr...

Page 17: ...tighten screws Check the compressed air connections for any signs of leakages if necessary seal Check the operating hours of the compressor aggregates If there are large differences in the compressor...

Page 18: ...n relief valve Change the controller at the display panel to manual Switch on the individual compressors aggregate manu ally using the display panel After approximately 5 seconds the non return relief...

Page 19: ...eak Check units and air supply for signs of leakages if necessary seal leaks Display Pressure sensor 1 defect Units do not function red LED Fault lit Connection between pressure sensor and controller...

Page 20: ...sary replace module 16 2 Further messages at display panel The following messages give information but do not indicate a fault or downtime of the units Message Probable cause Solution Bacterial filter...

Page 21: ...safety of the system according to current national and local code has been checked and confirmed Training in the operation and handling of the unit s has been carried out See back page The delivery r...

Page 22: ...Inc Page 22 Trained Personnel Log Name Signature Date Name Signature Date Name Signature Date Name Signature Date Name Signature Date Name Signature Date Name Signature Date Name Signature Date Form i...

Page 23: ...it will not be applied to product returns that exhibit damage due to shipping misuse careless handling or repairs by unauthorized personnel Credit or partial credit will not be issued until products p...

Page 24: ...er Evacuation System Cleaner Imaging Accessories Chemistry Processor Accessories For over 50 years Air Techniques has been a leading innovator and manufacturer of dental products Our priority is ensur...

Reviews: