2) Note the gauge reading when the filters are
dirty. Once the back flushing is done, the gauge
reading should be close to the gauge reading
when the filters were new.
3) To back flush the cartridge filters:
- Tum the AQE 2000 off.
- Attach a compressed air line to the air inlet.
Eighty to one hundred psig are required. The air
tank within the AQE 2000 will be filled from the
connected air supply; when the airflow stops, the
tank is full. Initiate back flushing by lifting and
releasing the toggle valve. Repeat the pulse
cycle several times for best results.
- Empty and reinstall the dust trays before
operating the unit.
5
E
XTENDING CARTRIDGE LIFE
1) Cartridge life can be e
xtended by
manually blowing out the cartridge filters.
2) To manually clean the filters, remove the filters
from the AQE 2000 and blow the dust off using a
hand-held blow gun attached to a shop air line.
Airflow should be directed from the inside of the
cartridge to the outside of the cartridge.
MAINTENANCE
The AQE 2000 will require minimum maintenance
to keep it in good operating condition. The motor is
totally enclosed, fan cooled with permanently
lubricated ball bearings. No maintenance is
required other than to reverse pulse the cartridges
and general cleaning of the cabinet, as needed.
Dust Trays