background image

AIR QUALITY ENGINEERING 

MODEL AQE 2000 CARTRIDGE SYSTEM 

Airborne contaminants enter the AQE 2000 

through the hood/arm assembly at a rate of 

1100 cubic feet of air per minute (cfm).  Heavy 

particles are propelled downward through the 

ventri and into the cleanout trays.  Smaller 

submicron particles are then trapped within the 

pleats of the two 99.8%  efficient  cartridge filters. 

DIMENSIONS:  46" H x 27" W x 37" D 

WEIGHT:  350 lbs. actual, 400 lbs. shipping 

POWER CONSUMPTION: 

120V- 10: 

208-240V - 10:

14 Amp maximum 

8 Amp maximum 

ARM ASSEMBLY: 13' Long x 6" Diameter or 

optional 8" diameter. Externally-supported arm 

with full 360 degree arm rotation. Arm assembly 

incorporates a gas springs and parallel lingage 

which provides easy up and down movement. 

HOOD: Single piece aluminum spun hood for 

durability. 

AIRFLOW VOLUME: 1100 CFM 

MOTOR: TEFC 1.5 HP, thermally-protected 

BLOWER: Direct-drive, backward incline, 

3450 RPM 

CABINET CONSTRUCTION: 16 gauge welded 

galvanized steel 

The cleaned air is then gently diffused out the 

bottom of the unit.  When the filter gauge indi­

cates that the cartridge filters are dirty, they are 

easily cleaned by connecting a shop air hose (80-

120 psi) to the unit and activating the reverse 

pulse system. 

CONTROLS: All models include control circuitry 

and thermal protection. 

POWER CORD: Ten-foot power cord with molded 

plug. 

CASTERS: Two large 8" diameter semi­pneumatic 

(front) wheels and two heavy-duty swivel casters 

(back). 

FINISH: Durable powder coat paint 

FILTRATION: Two high-efficiency cartridge filters, 

12 3/4" diameter x 22", 191 square feet of media 

each, 382 square feet total, 99.8% efficient at .5 

microns. 

FILTER ACCESS: Hinged side door 

FILTER CLEANING: Self-cleaning reverse pulse 

jet system which utilizes a one-inch diaphram 

valve. Requires 80-120 psi of shop­supplied 

compressed air. 1/4" NPT female fitting is 

provided to accept field-installed quick connector. 

FILTER GAUGE: Dwyer Minihelic II, indicates 

pressure up to 10" H

2

0. 

Summary of Contents for AQE2000

Page 1: ... complete self contained media air cleanerfor use in source capture applications in industry The ModelAQE2000 captures airborne contaminants such as welding smoke grinding dust plastic dust and otherfine particles II IUl ILIIIT lnl lllnl lllnl Manufacturer and Worldwide Distributor of Air Cleaning Systems for Over 25 Years ...

Page 2: ...PPLICATION OPERATION PackageContents Unpacking lnstructions SetupandOperation SERVICE Cleaning theCartridge Filters Extending Cartridge Life Maintenance TROUBLESHOOTING SCHEMATICS PARTSLIST WARRANTY PAGE 3 3 4 4 4 4 4 4 5 5 6 7 8 BackCover MadewithPrideintheUSA ...

Page 3: ...rive backward incline 3450 RPM CABINET CONSTRUCTION 16 gauge welded galvanized steel 3 The cleaned air is then gently diffused out the bottom of the unit When the filter gauge indi cates that the cartridge filters are dirty they are easily cleaned by connecting a shop air hose 80 120 psi to the unit and activating the reverse pulse system CONTROLS All models include control circuitry and thermal p...

Page 4: ...to indicate the load on the cartridge filters 4 UNPACKING INSTRUCTIONS 1 Inspect the boxes for damage before signing the delivery receipt from the carrier If the boxes appear to have been damaged note the damage on the delivery receipt and have the carrier initial the note 2 Carefully remove the packaging from the AQE 2000 SETUP AND OPERATION The arm assembly needs to be attached to the top of the...

Page 5: ...s for best results Empty and reinstall the dust trays before operating the unit 5 EXTENDING CARTRIDGE LIFE 1 Cartridge life can be extended by manually blowing out the cartridge filters 2 To manually clean the filters remove the filters from the AQE 2000 and blow the dust off using a hand held blow gun attached to a shop air line Airflow should be directed from the inside of the cartridge to the o...

Page 6: ...tycontrolsritch Replaceswitch Capture velocitylow Dirtyfilters Backflush Manually cleanor replace filters Obstruction inarmassembly Remove obstruciion Vibration Foreign objectin blower Remove obstruction Dirtyfilters Backflush manually cleanor replace Obstruction inarmassembly Remove obstruction Filtersnotcleaning Faultyairdiaphragm Checkto insureintemalairline Shopairpressure is in place Checkdia...

Page 7: ... I 1 B L A C K 11 GREEN WHITE ON OFF SWITCH 7 BLOWER MOTOR GREEN ...

Page 8: ...et connector 1 4 NPT HEPA Filter optional AIR QUALITY ENGINEERING INC 3340 WINPARK DRIVE 2 1 1 1 1 1 1 3 5 1 4 2 2 1 1 MINNEAPOLIS MINNESOTA 55427 2083 8 SINGLE PHASE PART NO 41167 10219 40051 37030 42129 10140 10226 30634 30360 30632 30041 30644 30633 07141 THREE PHASE PART NO 41167 10219 40053 37030 42156 10140 10226 30634 30360 30632 30041 30644 30633 07141 TOLL FREE 1 800 328 0787 TELEPHONE 61...

Page 9: ... v v v v AIR FLOW 37 4611 9 OUST fRAY r 28 5 ...

Page 10: ...uality Engineering Inc in eitheritsoriginal carton orina carton assuring similar protection oftheProduct with returned goodsnumber RTA clearly displayed onoutside ofcarton UNAUTHORIZED REPAIR A showing bytheoriginal purchaser thattheProduct hasnotbeenaltered repaired orserviced byanyone otherthananauthorized service technician usinggenuine AQEparts UNAUTHORIZED PARTS A showing bytheoriginal purcha...

Reviews: