AIR QUALITY ENGINEERING
MODEL AQE 2000 CARTRIDGE SYSTEM
Airborne contaminants enter the AQE 2000
through the hood/arm assembly at a rate of
1100 cubic feet of air per minute (cfm). Heavy
particles are propelled downward through the
ventri and into the cleanout trays. Smaller
submicron particles are then trapped within the
pleats of the two 99.8% efficient cartridge filters.
DIMENSIONS: 46" H x 27" W x 37" D
WEIGHT: 350 lbs. actual, 400 lbs. shipping
POWER CONSUMPTION:
120V- 10:
208-240V - 10:
14 Amp maximum
8 Amp maximum
ARM ASSEMBLY: 13' Long x 6" Diameter or
optional 8" diameter. Externally-supported arm
with full 360 degree arm rotation. Arm assembly
incorporates a gas springs and parallel lingage
which provides easy up and down movement.
HOOD: Single piece aluminum spun hood for
durability.
AIRFLOW VOLUME: 1100 CFM
MOTOR: TEFC 1.5 HP, thermally-protected
BLOWER: Direct-drive, backward incline,
3450 RPM
CABINET CONSTRUCTION: 16 gauge welded
galvanized steel
3
The cleaned air is then gently diffused out the
bottom of the unit. When the filter gauge indi
cates that the cartridge filters are dirty, they are
easily cleaned by connecting a shop air hose (80-
120 psi) to the unit and activating the reverse
pulse system.
CONTROLS: All models include control circuitry
and thermal protection.
POWER CORD: Ten-foot power cord with molded
plug.
CASTERS: Two large 8" diameter semipneumatic
(front) wheels and two heavy-duty swivel casters
(back).
FINISH: Durable powder coat paint
FILTRATION: Two high-efficiency cartridge filters,
12 3/4" diameter x 22", 191 square feet of media
each, 382 square feet total, 99.8% efficient at .5
microns.
FILTER ACCESS: Hinged side door
FILTER CLEANING: Self-cleaning reverse pulse
jet system which utilizes a one-inch diaphram
valve. Requires 80-120 psi of shopsupplied
compressed air. 1/4" NPT female fitting is
provided to accept field-installed quick connector.
FILTER GAUGE: Dwyer Minihelic II, indicates
pressure up to 10" H
2