AvAiLABLe ACCeSSORieS FOR USe wiTH 

RT-3000 SeRieS DUCT SMOKe DeTeCTORS

MSR- SERIES REMOTE ACCESSORIES

X* = Replace X* with w for white Cover Plate; R for Red Plate; S for Stainless Steel Plate

MSR-100 Series

 Features Visual Indicators:  Alarm, Pilot, Trouble  •  Buzzer:  Programmable for Alarm and Trouble Buzzer 

Silence:  Visual Notification and Ringback  •  Detector Test/Reset:  Key Operated • LED/Buzzer Test:  Push-Button Operated

MSR-100R/

X*

 

White Face Plate

MSR-100RS/

X*

/C  

White Face Plate; Strobe with Clear Lens

MSR-100RS/

X*

/O  

White Face Plate; Strobe with Opaque Lens

MSR-50RM Series

 Features Magnet Test, Pushbutton Reset, Visual Pilot, Trouble, Alarm LED

MSR-50RM/

X*

 

 Remote Indicator/Control Assembly w/ (color) Single Gang Cover Plate

MSR-50RMS Series

 Features MSR-50RM with Strobe and Double Gang Plate

MSR-50RMS/

X*

/C 

Remote Indicator/Control Assembly w/ Strobe Assembly (Clear Lens) 

MSR-50RMS/

X*

/O 

Remote Indicator/Control Assembly w/ Strobe Assembly (Opaque Lens) 

MSR-50RK

 

Series

 Feature Key Test & Reset with Visual Pilot, Trouble, Alarm LED

MSR-50RK/

X*

        

Remote Indicator/Control Assembly w/ (color) Single Gang Cover Plate

MSR-50RKS Series

 Features MSR-50RK with Strobe and Double Gang Plate

MSR-50RKS/

X*

/C 

Remote Indicator/Control Assembly w/ Strobe Assembly (Clear Lens)

MSR-50RKS/

X*

/O 

Remote Indicator/Control Assembly w/ Strobe Assembly (Opaque Lens); 

MSR-50SA Series

 Features plug-in combination Strobe (Visual) and Sounder (Audible) 

MSR-50SA/

X*

/C 

Module, Clear Lens with (color) Double Gang Cover Plate

MSR-50SA/

X*

/O 

Module, Opaque Lens with (color) Double Gang Cover Plate 

MS- and SHP- SERIES REMOTE ACCESSORIES

MS-RA 

Remote Alarm

MS-RA/R   

Remote Alarm, push button Test/Reset Switch

MS-RA/P/R 

Remote Alarm, Pilot, push-button Test/Reset Switch

MS-KA/R   

Remote Alarm, key-operated Test/Switch

MS-KA/P/R 

Remote Alarm, Pilot, key-operated Test/Reset Switch

MS-RA/P   

Remote Alarm, Pilot

MS-RH 

 

Remote Alarm Horn

MS-RH/KA/P/R 

Remote Alarm, Pilot, Horn, key-operated Test/Reset Switch

MS-RH/P/A 

Remote Alarm, Pilot, Horn 

MS-RH/KA/P/A/T 

Remote Alarm, Trouble, Pilot, Horn, key-operated Test/Reset Switch

MS-RA/P/T 

Remote Pilot, Trouble

MS-RA/FT/P 

Remote Pilot, Trouble, push-button Test/Reset Switch

MS-KA/P/R/T 

Remote Pilot, Trouble, key-operated Test/Reset Switch

MS-RD 

 

Remote Alarm

MS-F/T 

 

Remote Trouble 

SHP24-1575R 

Horn/Strobe, red housing, clear cover 

SHP24-1575O 

Horn/Strobe, white housing, opaque cover

SHP24-1575W 

Horn/Strobe, white housing, clear cover

SMOKE  TEST GAS
TG-2000 

Solo Aerosol Test Gas with Nozzle for Test Port

NOTCHED SAMPLING TUBES

STN-1.0    For duct widths of 6" to 1.0'          STN-2.5    For duct widths of 1.0' to 3.0'

STN-5.0    For duct widths of 3.0' to 5.0'        STN-10.0  For duct widths of 5.0' to 10.0'

REPLACEMENT SMOKE DETECTOR HEADS
55000-225APO 

S65A Ionization Detector Replacement Head 

55000-328APO 

S65A Photoelectric Detector Replacement Head 

POWER SUPPLIES
T-PB 202-1  

24VAC @ 4.0A Class I Power Supply

T-PB 202-0  

24VAC @ 4.0A Class I Power Supply

T-PB 303-1  

24VAC @ 3.0A Class II Power Supply

T-PB 303-0  

24VAC @ 3.0A Class II Power Supply

FOR TECHNICAL SUPPORT CALL TOLL FREE 888-332-2241 OR 248-332-3900 

Summary of Contents for RT-3000-N

Page 1: ...t Any example applications shown are subject to the most current enforced local national codes standards approvals certifications and or the authority having jurisdic tion All of these resources as well as the specific manufacturer of any shown or mentioned related equipment should be consulted prior to any implementation For further information or assistance concerning this product contact Air Pr...

Page 2: ...d into the HVAC duct Air flowing through the duct is forced into the air intake inlet tube via the air intake holes facing the airflow and passes over the detector head The air will be drawn out via the exhaust tube back into the HVAC duct A 7 exhaust tube is provided in the installation kit When the concentration of smoke particles suspended in the air stream reach the alarm threshold of the dete...

Page 3: ...be into place against the spring loaded retainer and turn to the correct position allowing the key to Mechanical Installation lock the tube in the desired orientation For front side installation simply rotate the tube retainer so that the tube may be inserted and oriented properly Once the tube is installed rotate the retainer back into place to lock down the tube Ensure air intake sampling tube i...

Page 4: ...VER REMOVAL and the unit will be energized The green pilot LED will be illuminated and when pressing the test reset button TEST RESET the red alarm LED will be illuminated This test confirms the correct basic operation of the duct smoke unit excluding the detector head see functional testing Shut down WIRING Example In alarm NC and COM will open interrupting voltage supply to fan NC COM NO ALARM 1...

Page 5: ...nly no tools single point cover assembly when the unit cover is on and the latch is in closed position the RT 3000 is secure and weathertight Patented Maintenance Mode offers 3 minute interval for test and maintenance functions with no extra trouble reports to the system automatically shuts off when cover latch engages Patented tether holds cover to unit and allows hands free reference to wiring d...

Page 6: ...ACU Alarm COM NO COM NO COM NO COM NO facu alarm trouble NO com nc com NO C NC C form A Alarm form b trouble 30vdc 1 0a 30vdc 7 0a SAMPLE CONTROL unit WIRING STYLE d CLASS A IDC Supervised A fault condition will not inhibit an alarm response Trouble contacts are shown in energized condition Under normal operation contacts will be held as shown msr remote accessory wiring ms remote accessory wiring...

Page 7: ...interconnect al1 al2 t r s h common alarm link common link reference common test reset in alarm out alarm out common alarm horn strobe options The following diagrams show interconnection of the RT 3000 Series to other duct smoke detectors manufactured by Air Products and Controls specifically the SL 2000 Series the HS 100 Special Application Series and the SM 501 Series Up to 30 Air Products units...

Page 8: ...afe to perform test maintenance functions without extra reports to the system Determine Correct Operation ofthe Head MagnetTest 1 Place the square short sided end of the magnet provided with the installation kit on the grey section of the housing inline with the area designated Test Magnet Allow at least five seconds for alarm initiation 2 Upon alarm initiation both the detector head LED and redAL...

Page 9: ...combination Strobe Visual and Sounder Audible MSR 50SA X C Module Clear Lens with color Double Gang Cover Plate MSR 50SA X O Module Opaque Lens with color Double Gang Cover Plate MS and SHP SERIES REMOTE ACCESSORIES MS RA Remote Alarm MS RA R Remote Alarm push button Test Reset Switch MS RA P R Remote Alarm Pilot push button Test Reset Switch MS KA R Remote Alarm key operated Test Switch MS KA P R...

Reviews: