Feniks FUTURE Instruction Manual, No.
033-02-200
edition
IA
, 2012, page
9
of
36
AIR-POL Sp. z o.o.
– 05-120 Legionowo, ul. Olszankowa 52, www.air-pol.com.pl
tel.: (+4822) 774 0711, (+4822) 784 1595, (+4822) 774 4832, fax (+4822) 784 9640, @: [email protected]
3.
AUTOMATIC ACTIVATION DEVICE (AAD) ASSEMBLY
All Feniks containers are delivered with components required for the mounting of CYPRES AADs duly tested and approved
for use by Airtec, the AAD manufacturer. Any AAD resembling CYPRES in design may be mounted on the Feniks container,
provided that such an AAD:
•
Is fitted with a central unit mounted on the bottom surface of the reserve parachute container,
•
Is fitted with a device to cut a closing loop mounted on the side flap above the spring-loaded pilot chute,
•
Is fitted with a control panel appropriate for mounting in a pouch on the top of the container.
Prior to AAD assembly, read its owner’s manual, and become familiar with its limitations and specificity. Check for service
validity, proper battery condition, and whether the device can be switched on properly.
Proceed with assembly only when the AAD is switched off.
Photo No. 7
Components required for CYPRES AAD assembly
are placed in each delivered unit of the Feniks
harness/container system.
•
Central unit pouch (1)
•
Cutter cable orifice (2)
•
Cutter cable casing (3)
•
Flexible cutter handle/tape (4)
•
Entry point of the control panel cable (5)
•
Exit point of the control panel cable (6)
•
Control panel pouch in the top of the container
(7).
Photo No. 8
1.
Place the AAD central unit in the pouch (1) on
the bottom surface of the reserve parachute
container.
2.
Thread the AAD cutter through the orifice (2)
in the bottom flap, then through the casing (3)
on the side flap, and place the cutter’s
operating edge in the rubber pouch (4).
3.
Place any excess cable in the AAD pouch (1),
following the AAD owner’s manual.
Photo No. 9
4.
Thread the control panel through the orifice in
the bottom of the reserve parachute container
(5) and through to the exit point in the upper
part (6), then – pushing it through the opening
– place the control panel in the transparent
pouch under the last flap (7).
5.
Place any excess cable in the AAD pouch (1),
following the AAD owner’s manual. It is
possible to place the control panel cable in a
casing on the bottom of the container (5).
6.
Make sure all cables are protected against
sharp edges, and exposed as little as possible
outside their respective casings/pouches.
1
2
5
6
3
4
7
6