E
“FULL TANK” ALERT:
The appliance produces a sound signal once the tank is full. The appliance
turns off and the indicator becomes red.
• To empty the tank:
Éteignez l’appareil, tirez le réservoir
grâce à la poignée prévue à cet effet, videz les condensats
puis repositionnez-le. Appuyez sur le bouton ON/OFF et
choisissez le mode de fonctionnement souhaité.
• Tank detection:
The dehumidifier is equipped with a tank
positioning sensor. As a matter of security, the product
turns off if the tank is missing or not properly placed.
USE PRECAUTIONS
ADDITIONAL FUNCTIONS
AUTOMATIC ANTIFREEZE FUNCTION (DEFROST):
The appliance automatically enters in defrost
function if the ambient temperature is between 5°C and 15°C. Every now and then, the
compressor stops but the fan continues to work.
CONTINUOUS DRAINAGE:
Thanks to the continuous drainage hose, the appliance will work
independently without having to empty the tank. Make sure the hose is not bent and that it is
placed on a downward slope so that water can easily drain away. Do not modify or extend
the drainage hose.
1. Remove the tank.
2. Connect the drainage hose.
3. Pass the hose through the opening provided for this purpose before repositioning the tank.
Do not remove the float from the tank
because it will prevent the appliance from
starting.
Make sure the tank is properly positioned
and pushed in. Otherwise, it will prevent the
appliance from starting.
11