5.  Raise top chimney in place over horizontal mounting bracket and secure in place 

with the two included #6 x 3/8" screws 

(Figure 9).

SECTION 6

Finishing the Installation

1.  Install the appropriate filters.
 

Charcoal Filters:

 If the range hood will be run ductless, remove and discard the 

grease filters that were included with the unit and install model BCCF-03 charcoal 

filters instead.

 

Grease Filters:

 If the range hood will be vented to the exterior of the home, install 

the grease filters supplied with the hood by sliding tab at rear of filter into slot in 

hood. While holding in handle of filter, lift filter into palce and release handle. the 

filter should snap securely into place 

(Figure 10).

2.  Remove any protective plastic adhered to the range hood.

3.  Turn switches to the OFF ( • ) position and restore power. Test that the light and the 

fan are operating properly.

4.  If there is any vibration noise, check for the source and try to tighten fasteners or 

adjust the tape to make a tighter connection or seal.

SECTION 7

Operation
Controls

Your Range Hood is equipped with two sliding switches with one controlling the lighting and 

the other controlling the exhaust fan. The light control has two positions, ON ( I ) and OFF  ( 

O

 ). 

The fan is a four position control, HIGH (III), MEDIUM (II),LOW (I), and OFF ( • )

 (Figure 11).

www.airkinglimited.com

6728027 Rev. B 12-09

4 of 12

SECTION 8

Maintenance

CAUTION: 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE SERVICING THE UNIT.

Grease Filters

Included with your range hood are aluminum grease filters that should be washed at 

least once a month. The filters are dishwasher safe and should be washed in a mild 

soap or detergent. Refer to 

Step 3

 of 

Section 1

 

Preparing the Range Hood

, to remove 

filters. If the grease filters become damaged, replace with Air King Model BCGF-01 

Grease Filter.

Charcoal Odor Filter

If you have installed the optional charcoal odor filters, they cannot be washed and must 

be discarded and replaced when they become noticeably dirty, have stopped filtering 

the odors, or at least once per year. Replace with Air King Model BCCF-03 Odor Filters.

Changing the Lamp

Remove the lamp cover on the underside of the hood and remove the lamp by gently 

rocking it back and forth while applying outward pressure to release the lamp from the 

base. Replace with Air King model 26WFL or a compatible CFTR26W/GX24q/835 lamp.
 

Sylvania model: 20881

 

Phillips model: 26824

Fuse

To replace the fuse, turn the fuse cap located next to the wire connector counter clock-

wise and pull out. Replace with a Bussman MDA 125-Volt, 1.5 Amp Max. fuse (models 

VAL30AB and VAL36AB utilize a 3 Amp Max fuse). Reinstall the fuse back into the hood.

Cleaning

CAUTION:

 DO NOT USE GASOLINE, BENZINE, THINNER, HARSH CLEANSERS, 

ETC., AS THEY MAY DAMAGE THE RANGE HOOD.

1.  Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with 

a soft cloth. 

NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS

. Completely 

dry before restoring power. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

2.  The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates 

over time. The fan is permanently lubricated and does not require oiling.

Figure 11

Troubleshooting Guide

    Trouble 

 

Probable Cause 

 

Suggested Remedy

  1.  Hood does not operate when the switch is on. 

1a.  A fuse may be blown or a circuit tripped. 

1a.  Replace fuse or reset circuit breaker.

     

1b.  Wiring is not connected properly. 

1b.  Turn off power to unit. Check that all wires are connected.

  2.  Hood is operating, but air moves slower than normal. 

2. 

Obstruction in the exhaust ducting. 

2. 

Check for any obstructions in the ducting including filter.

  3.  Hood is making a rattling noise. 

3a.  Filters are loose. 

3a.  Turn off power to unit. Check that all filter are securely in place.

     

3b.  Duct connection is loose. 

3b.  Turn off power to unit. Check that duct connection is tight.

Installer: 

 

Installation Date: 

Place of Purchase: 

 

Model Number: 

Filter

Figure 10

Summary of Contents for ESVAL30S

Page 1: ...t damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEI...

Page 2: ...3 16 drill bit Install wall anchors into the drilled holes one for each hole If installing into other material brick cement plaster etc choose an appropriate fastner capable of supporting the weight o...

Page 3: ...the chimney are secured in place on the indents of the vertical chimney bracket and the backside of the chimney fits between the hood and the wall with the bottom tabs overlapping the back lip of the...

Page 4: ...installed the optional charcoal odor filters they cannot be washed and must be discarded and replaced when they become noticeably dirty have stopped filtering the odors or at least once per year Repla...

Page 5: ...XPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these...

Page 6: ...www airkinglimited com 6728027 Rev B 12 09 6 of 12...

Page 7: ...UER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent toujours tre...

Page 8: ...r s un pour chaque trou Si vous installez sur d autres mat riels brique ciment pl tre etc choisissez une fixation appropri e capable de soutenir le poids de la hotte Accrochez la hotte au dessus des a...

Page 9: ...re ce moment 3 Glissez la chemin e en place de fa on ce que les languettes de dessus de chemin e soient fix es en place sur les creux du support vertical de la chemin e et le derri re de la chemin e a...

Page 10: ...re jet s et remplac s lorsqu ils deviennent sales de fa on remarquable qu ils aient cess de filtrer les odeurs ou au moins une fois par ann e Remplacer les filtres anti odeurs avec le mod le BCCF 03 d...

Page 11: ...riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous donne des dro...

Page 12: ...www airkinglimited com 6728027 Rev B 12 09 12 of 12...

Reviews: