INSTALLATION INSTRUCTIONS
CAUTION:

 

MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

SECTION 1

Preparing the Range Hood

1.  Unpack hood from the carton and confirm that all pieces are present. In addition to 

the range hood you should have:

 

 

2 -  Chimney Sections

 

 

1 -  Package containing: 

 

 

 

1 - duct collar

 

 

 

2 - chimney brackets

 

 

 

8 - #6 x 1" mounting screws with wall anchors

 

 

 

2 - #6 x 3/8" self threading screws (chimney upper)

 

 

30" models: 2 - Aluminum Grease Filters (shipped installed)

 

 

36" models: 3 - Aluminum Grease Filters (shipped installed)

 

 

1 -  Lampe fluorescente de 26 watts

 

 

1 -  Instruction/Safety Sheet   

NOTE:

 Some hoods may be shipped with a protective plastic adhered to the range 

hood. It is recommended to leave this in place during installation to protect the hood 

from scratching. Remove when the installation is complete.
2.  Lay the back side of the hood flat on a table. Use a piece of cardboard to avoid 

damaging the table or the hood.

3.  Remove the lens cover on the underside of the range hood and install the included 

26 watt fluorescent lamp 

(Figure 1).

SECTION 2

Installing the Range Hood

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL 

BEFORE STARTING INSTALLATION.

CAUTION:

WHEN CUTTING OR DRILLING INTO WALL DO NOT DAMAGE 

ELECTRICAL WIRING AND OTHER HIDDEN UTILITIES.

1.  Refer to the mounting hole drawing provided with the unit. Locate and mark the upper 

keyhole positions on the wall. If installing onto drywall, drill holes into wall using a 

3/16" drill bit. Install wall anchors into the drilled holes (one for each hole). Install (2) 

provided #6 x 1" screws, leaving a 1/8" gap between the screw head and the wall. 

If installing into other material (brick, cement, plaster, etc.) choose an appropriate 

fastner capable of supporting the weight of the hood. Line up the keyholes in the 

hood with the screws and position in place. Hang the hood over the keyhole anchors 

and verify that the hood is centered, plum and level 

(Figure 2).

www.airkinglimited.com

6728027 Rev. B 12-09

2 of 12

2.  With the hood hanging in place from the top screws, mark the location of the 

lower holes. If installing onto drywall, remove the hood and drill holes into wall 

using a 3/16" drill bit. Install wall anchors into the drilled holes (one for each hole). 

If installing into other material (brick, cement, plaster, etc.) choose an appropriate 

fastner capable of supporting the weight of the hood. Hang the hood over the keyhole 

anchors and verify that the hood is centered, level and the bottom holes line up with 

the anchors. Install the provided #6 x 1" screws into the anchors 

(Figure 3)

. Tighten 

all screws completely and reinstall the Grease filters

.

SECTION 3

Ducting

CAUTION:

 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL 

BUILDING CODES.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

1.  Install the included duct collar to the hood with two of the provided #6 blunt tip 

screws 

(Figure 4).

1.  Connect the ducting to the duct collar and secure in place using tape to seal all 

joints 

(Figure 4).

NOTE:

 The duct connector is 5.8" in diameter (for 6" round ducting) and the center is 

located 3-3/16" inches from the back wall.

CAUTION:

 ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR 

ROOF CAP.

SECTION 4

Wiring

CAUTION:

 ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE 

WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE 

UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE 

SERVICES OF A QUALIFIED ELECTRICIAN.

1.  Remove wire compartment cover by removing the screw then sliding it outward. 

Choose the most convenient electrical knockout and remove using a straight-

blade screw driver.

2.  Run wiring from an approved source carrying the appropriate rating. One neutral 

(White), one ground (green or bare copper), and one hot (Black). Secure the electrical 

wires to the wire compartment with an approved electrical connector. Make sure you 

leave enough wiring in the box to make the connection to the hood.

3.  Connect the White wire from the range hood to the White wire from the supply, and the 

Black wire from the range hood to the Black wire of the supply. Connect the ground 

wire from the home (green or bare) and the Green wire from the range hood. Use 

approved methods for all connections. Reinstall the wire compartment by sliding the 

tabs back into the holes then reinstalling the screw that was removed eariler. Make 

sure all wiring is securely contained within the wire compartment 

(Figure 5).

Figure 4

Duct Collar

Ducting

Hood

Figure 2

Upper Keyholes

Side View

Figure 3

Holes

Side View

Figure 1

Lamp

Pin

Summary of Contents for ESVAL30S

Page 1: ...t damage electrical wiring and other hidden utilities CAUTION TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEI...

Page 2: ...3 16 drill bit Install wall anchors into the drilled holes one for each hole If installing into other material brick cement plaster etc choose an appropriate fastner capable of supporting the weight o...

Page 3: ...the chimney are secured in place on the indents of the vertical chimney bracket and the backside of the chimney fits between the hood and the wall with the bottom tabs overlapping the back lip of the...

Page 4: ...installed the optional charcoal odor filters they cannot be washed and must be discarded and replaced when they become noticeably dirty have stopped filtering the odors or at least once per year Repla...

Page 5: ...XPIRATION OF THE WARRANTY PERIOD Some states and provinces do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these...

Page 6: ...www airkinglimited com 6728027 Rev B 12 09 6 of 12...

Page 7: ...UER L AIR VERS L EXT RIEUR NE PAS VACUER L AIR DANS DES ESPACES DANS LES MURS LES PLAFONDS OU LES GRENIERS LES GALERIES TECHNIQUES OU LES GARAGES d Les ventilateurs avec conduits doivent toujours tre...

Page 8: ...r s un pour chaque trou Si vous installez sur d autres mat riels brique ciment pl tre etc choisissez une fixation appropri e capable de soutenir le poids de la hotte Accrochez la hotte au dessus des a...

Page 9: ...re ce moment 3 Glissez la chemin e en place de fa on ce que les languettes de dessus de chemin e soient fix es en place sur les creux du support vertical de la chemin e et le derri re de la chemin e a...

Page 10: ...re jet s et remplac s lorsqu ils deviennent sales de fa on remarquable qu ils aient cess de filtrer les odeurs ou au moins une fois par ann e Remplacer les filtres anti odeurs avec le mod le BCCF 03 d...

Page 11: ...riode de garantie ou l exclusion ou la restriction des dommages accidentels ou indirects et par cons quent les pr sentes restrictions ne peuvent pas s appliquer La pr sente garantie vous donne des dro...

Page 12: ...www airkinglimited com 6728027 Rev B 12 09 12 of 12...