Air King AK100FL Operating Manual Download Page 6

www.airkinglimited.com

210952012 Rev. B 8-06

6 of 12

1

REPLACEMENT PARTS DIAGRAM

#

Qty. Description

Replacement Part #

1

1

Fan Housing

5S1202008

2

4

Mounting Rails

5S1299002

3

1

External Wire Cover

5S1202007

4

1

Screw

5S1999010

5

1

Collar

5S1299003

6

1

Damper

5S1299004

7

1

Polarized Receptacle

5S1999001

8

1

Screw

5S1999010

9

1

Motor

5S1202009

10

4

Screw

5S1202010

11

1

Motor Plate

5S1202011

12

2

Hex Nut

5S1202012

13

1

Blower Wheel

5S1202013

14

1

Venturi

5S1202014

15

1

Screw

5S1999011

16

1

Light Reflector - AK100L

5S1202015

1

Light Reflector - AK100FL

5S1202023

#

Qty. Description

Replacement Part #

17

1

Lamp Harness - AK100L

5S1202016

1

Lamp Harness - AK100FL

5S1202024

18

1

Clip

5S1202017

19

1

Bushing

5S1202018

20

2

Screw

5S1202019

21

1

Glass Lens

5S5202001

22

1

Grill

5S1202020

23

4

Lens Clip

5S1202021

24

2

Grill Spring

5S1202006

25

1

14 ga Ground Wire

5S1999003

26

1

#10 Ground Screw

5S1999002

27

1

Wire Cover & Light Harness

5S1202022

28

1

FL Lamp Holder - AK100FL*

5S1202025

29

1

Ballast - AK100FL*

5S1202026

30

2

Screw - AK100FL*

5S1202027

2

2

21

22

23

10

3

4

28

30

5

6

7

8

9

11

12

13

14

15

16

17

18

19

20

24

25

26

27

29

*

* AK100FL only

Summary of Contents for AK100FL

Page 1: ...fire related construction 5 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equip...

Page 2: ...the location for your fan To ensure the best air and sound performance it is recommended that the length of ducting and the number of elbows be kept to a minimum and that insulated hard ducting be use...

Page 3: ...from the fan Figure 8 Use approved methods for all connections NOTE The fan s receptacle wires might need to be pulled outside compartment for connection Only pull the loose wires outside of compartme...

Page 4: ...RE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT 1 Cleaning the Grill Remove grill and use a mild detergent such as dishwashing liquid and dry with a soft cloth NEVER USE ANY ABRASI...

Page 5: ...hased Failure to meet these requirements will void your warranty Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or i...

Page 6: ...14 15 1 Screw 5S1999011 16 1 Light Reflector AK100L 5S1202015 1 Light Reflector AK100FL 5S1202023 Qty Description Replacement Part 17 1 Lamp Harness AK100L 5S1202016 1 Lamp Harness AK100FL 5S1202024 1...

Page 7: ...our la bonne combustion et l vacuation de gaz par le conduit chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de...

Page 8: ...E COMMENCER L INSTALLATION SECTION 1 Pr paration du Ventilateur d vacuation 1 Sortir le ventilateur de sa boite et confirmer que toutes les pi ces sont pr sentes En plus du ventilateur d vacuation vou...

Page 9: ...e la terre de la maison au fil vert du ventilateur Figure 8 Utiliser des m thodes de raccordement approuv es pour toutes les connexions REMARQUE les fils du r ceptacle du ventilateur pourraient n cess...

Page 10: ...re tout en appliquant une pression externe pour d gager l ampoule du socle Remplacer l ampoule avec une ampoule fluorescente d un maximum de 26 watts quad 2 tiges Lumi re de Nuit AK100L AK100FL D vis...

Page 11: ...d achat originale Air King qui d montrera La date d achat l endroit de l achat et le mod le achet Le manquement rencontrer ces exigences annulera votre garantie Air King ne sera pas tenu responsable...

Page 12: ...6 1 R flecteur de la Lumi re AK100L 5S1202015 1 R flecteur de la Lumi re AK100FL 5S1202023 de pi ce Qty Description de remplacement 17 1 Harnais de la Lampe AK100L 5S1202016 1 Harnais de la Lampe AK10...

Reviews: