background image

NOTE:

 If the fan motor plug is 

connected to the fan housing 

receptacle, unplug so the blower 

assembly can be completely removed.

2. 

Continuous Ventilation:

 For two speed fans wired for continuous ventilation, connect 

the White wire of the fan to the White (Neutral) wire from the power source. Connect the 

ground wire from the house to the green wire from the fan housing. Run 2 wires from a 

properly grounded wall switch (not included) to the fan. Connect the Black wire of the fan 

to the Black wire (Hot) from the power source. Connect the Hot Yellow wire from the fan 

to the input of the switch. Connect the second Yellow wire from the fan to the output side 

of the switch. Closing the switch will change from normal to high speed.  

(Figure 9)

.

2b. 

Intermittent Ventilation:

 For two speed fans wired for intermittent ventilation with a 

standard duplex toggle switch (such as Leviton 5224-2W not included). Connect the 

White wire of the fan to the White (Neutral) wire from the power source. Connect the 

ground wire from the fan to the ground wire from the power source. Properly ground the 

switches. Connect the black wire from the supply to one side of the top switch. Connect 

the black wire from the fan to the other side of the top switch, Connect 1 yellow wire 

from the fan to each side of the bottom switch. The top switch turns the fan On & Off, the 

bottom switch changes speed between high and low

 (Figure 10)

.

NOTE:

 Unit must be grounded according to all local and national codes.

4.  Reinstall both the wire compartment cover and the fan’s venturi by reversing the 

instructions in Step 1b of Section 5 Wiring. Make sure all wires are contained within the 

wire compartment.

www.airkinglimited.com

A210952011 Rev. K 11-18

3 of 8

SECTION 6

Completing the Installation

1.  Use a sealant appropriate for contact with the building materials present and for the 

temperature requirements of the installation to prevent air leakage from unconditioned 

spaces is recommended. If gaps between unit housing and ceiling are great, additional 

material (backing rod, ceiling material) may be required.

NOTE:

 This fan is rated for direct insulation contact (Type IC) and it is recommended that this fan 

be completely covered by insulation in order to reduce heat loss or gain to unconditioned space.
2.  Plug the fan’s quick connect motor cord into the receptacle located on the wire 

compartment cover. The cord will only fit one way into the receptacle 

(Figure 11).

3.  Install the grill by squeezing the two ends of the springs together and installing them up 

into the slots on the fan’s housing. Push the grill up into position 

(Figure 12).

4.  Restore power and test your installation.

SECTION 7

Setting the Humidistat 

(Model AK100DH Only)

This fan may be equipped with a humidity sensor that automatically turns the fan on (or to 

high speed on dual speed models) when humidity is above set point and off (or back to low 

speed on dual speed models) when humidity is at or below set point. If the fan is operating 

too long or not enough, first check to see the humidity sensor set point. In cases where the 

ambient humidity level of the room rises higher than the preset level, the fan will turn on even 

if the room is not occupied. This helps prevent conditions that lead to mold growth.

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE SERVICING THE UNIT.

1. 

To set the desired humidity level of the room, remove the grill and locate the 

dehumidistat dial located on the wire compartment cover. 

2. 

Set the dial to the relative humidity you want the fan to maintain usually between 50 & 

80%. Moist climates will require higher settings than dry climates. When the humidity 

level of the room is below this setting the fan will remain off (or low speed on dual speed 

models). When the humidity level rises above this setting the fan will turn on (or to high 

speed on dual speed models) and run until the humidity level falls below this setting. 

3.  Reinstall the grill and restore power.

SECTION 8

Use and Care

CAUTION:

 MAKE SURE POWER IS SWITCHED OFF AT 

SERVICE PANEL BEFORE STARTING INSTALLATION.

1. 

Cleaning the Grill:

 Remove grill and use a mild detergent, such as dishwashing liquid, 

and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. 

Completely dry grill before reinstalling. Refer to instructions in 

Section 6

 

Finishing the 

Installation

, to reinstall grill.

2. 

Cleaning the Fan Assembly:

 Wipe all parts with a dry cloth or gently vacuum the fan. 

NEVER IMMERSE ELECTRICAL PARTS IN WATER.

Wire 

Compartment 

Cover

Figure 7

Screws

Venturi

Figure 11

Screw

Wire

Compartment 

Cover

Screw

Figure 8

Wire

Compartment 

Cover

Figure 12

Figure 10

Supply from house

Neutral (White)

Ground (Green or Bare)

Fa

n

Switch

(by others)

Neutral (White)

Green

Black

Yellow

Yellow

Black

By others

Figure 9

Supply from house

Neutral (White)

Ground (Green or Bare)

Fa

n

Switch

(by others)

Neutral (White)

Green

Black

Yellow

Yellow

By others

Black

Summary of Contents for AK100DH

Page 1: ...t air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safe...

Page 2: ...ST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES www airkinglimited com A210952011 Rev K 11 18 2 of 8 NOTE The ducting from this fan to the outside of the building has a strong effect on the air flow...

Page 3: ...wire compartment cover The cord will only fit one way into the receptacle Figure 11 3 Install the grill by squeezing the two ends of the springs together and installing them up into the slots on the f...

Page 4: ...WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY LAST FIVE YEARS FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT...

Page 5: ...t chemin e provenant d quipement de br lage au combustible pour pr venir un refoulement Suivre les directives du fabricant de l quipement de chauffage et les normes de s curit telles que celles publi...

Page 6: ...REMARQUE La canalisation de ce ventilateur l ext rieur du b timent a un effet important sur le flux d air le bruit et la consommation d nergie du ventilateur Utilisez la route de canalisation la plus...

Page 7: ...e mani re dans le r ceptacle Figure 11 3 Installer la grille en pressant ensemble les deux extr mit s des ressorts et en les installant dans les fentes du ch ssis du ventilateur Pousser la grille en p...

Page 8: ...on de retour de Air King apr s les r parations ou le remplacement de garantie TOUTES LES GARANTIES EXPRESSES OU TACITES COMPRENANT SANS LIMITATION TOUTE GARANTIE TACITE DE VALEUR MARCHANDE DURENT CINQ...

Reviews: