40
Degrees F or
Degrees C
Setting 1
•
Press the “Up” arrow to change
temperature from °F to °C.
•
Press the “Down” arrow to change
temperature from °C to °F.
Low
temperature
alarm setpoint
Setting 2
•
Press “Settings” button to advance to
Setting 2.
•
Press the “Up” or “Down” arrow buttons
to adjust to the desired setpoint. Factory
default is 50°F (10°C).
High
temperature
alarm setpoint
Setting 3
•
Press “Settings” button to advance to
Setting 3.
•
Press the “Up” or “Down” arrow buttons
to adjust to the desired setpoint. Factory
default is 65°F (18°C).
Low humidity
alarm set
point
Setting 4
•
Press “Settings” button to advance to
Setting 4.
•
Press t
he “Up” or “Down” arrow buttons
to adjust to the desired setpoint. Factory
default is 5%.
High humidity
alarm setpoint
Setting 5
•
Press “Settings” button to advance to
Setting 5.
•
Press the up or down arrow buttons to
adjust to the desired setpoint. Factory
default is 95%.
Add or
remove
humidifier
Setting 6
•
Press “Settings” button to advance to
Setting 6.
•
Press the “Up” or “Down” arrow buttons
to adjust to the desired setpoint. Factory
default is zero (0).
Zero (0) = No humidifier
One (1) = Integral Wine Guardian
mounted humidifier
Two (2) = Stand-alone remote mounted
humidifier
Settings
– Press and hold the “Settings” button for five (5) seconds to access the
following settings.
TAP AN ARROW KEY ONCE TO WAKE UP THE CONTROLLER
Summary of Contents for WINE GUARDIAN DS025
Page 13: ...13 Overview of the Evaporator Fig 1...
Page 14: ...14 Overview of the Condenser Fig 2...
Page 15: ...15 Refrigeration Illustration Fig 3...
Page 16: ...16 Wiring Diagram for DS025 WGS40 Fig 4...
Page 17: ...17 Wiring Diagram for DS025 WGS40 cont Fig 5...
Page 18: ...18 Wiring Diagram for DS025 WGS40 cont Fig 6...