8.0 Keyless Lock
The SSC4500DX is supplied with a keypad style lock to protect the contents of the cabinet. The
lock can be opened by typing the MASTER code of 11335577 or the USER code of 2244.
These codes can be changed for local use.
2) Programming/Changing code:
a) To program, the lock must be in the open position with the # button visible.
Every program command must commence by pressing the # button, followed
by either the Master code or user code.
b) #Master code 01 New Master Code New master code
Example: #11335577 01 12345678 12345678
c) #Master code 02 User Code
Example: #11335577 02 9999
3) Battery Replacement: The lock should provide well in excess of 15,000
openings of 4 seconds each from two (2) AAA 1,5V batteries. To fit new batteries,
remove the upper fixing bolt and swing the lock downward over the edge of the door.
Replace the batteries and refit the lock. Dispose of used batteries properly.
4) Emergency Override: If the batteries should die between maintenance cycles, the
Figure: 11 Open
Battery Failure
Contact points
Figure: 10 Locked
Cam
Handle
Keypad
Code Rejected
Low Battery Indicator
Code
Accepted