background image

This  

AIR GUNSA

spray guns kit complies to ATEX regulations 94/9/EC, protection level:

II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. 

IMPORTANT

This spray gun should be operated only by an adequately trained operator, for safe use and maintenance of the equipment. Any
misuse or handling other than those indicated in this Instruction Manual is not covered by guarantee.  AIR GUNSA disclaims all
responsibility for any accident or damage caused by failure to observe the operational and safety procedures as from this man-
ual. In the interest of user friendliness, this manual contains information in a brief and concise form.
For any additional information you may require regarding spray guns operations, or if any missing parts or any damage during
transportation is found, please contact your nearest AIR GUNSA Company (see last cover page).

IMPORTANT SPECIFICATIONS

Be sure to observe warnings and cautions in this instruction manual.
If not, it can cause paint ejection and serious bodily injury by drawing organic solvent.
Be sure to observe following        marked items which are especially important.

WARNING

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or pro-
perty damage.

IMPORTANT

Indicates notes which we ask you to observe.  The safety precautions in this instruction manual are the mini-
mum necessary conditions.  Follow national and local regulations regarding fire prevention, electricity and 
safety as well as your own company regulations.

TECHNICAL SPECIFICATIONS

Manufactured by: 

AIR GUNSA _ Anest Iwata Gruop

(1)

Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows.

(2)

Paint viscosity:

21 sec/Ford cup#4 AZ10 HTE SP
54 sec/Ford cup#4 AZ10 HTE PC

Before use, adjustment or maintenance, it is important to read this instruction manual very 
carefully. This manual must be stored in a safe place for any future reference that may be necessary. 

GB

Model

Nozzle Air 

Cap

(1) 

Atomizing

(2) 

Fluid 

Air 

Pattern

Orifice

set Mark

Air pressure

Output

Consumption

Width

Ø mm (in)

bar (PSI)

ml/min 

Nl/min (cfm)

mm (in)

AZ10 HTE SP / AZ10 HTE SP AV / AZ10 HTE PC Pressure feed

AZ10 HTE SP 0.8

0.8 (0.031)

08

150

210 (7.41)

190 (7.48)

AZ10 HTE SP 1.0

1.0 (0.039)

10

150

210 (7.41)

200 (7.87)

AZ10 HTE SP 1.3

1.3 (0.051)

13

200

210 (7.41)

230 (9.05)

AZ10 HTE SP 1.5

1.5 (0.059)

15

200

210 (7.41)

240 (9.45)

AZ10 HTE SP 1.8

1.8 (0.070)

18

250

280 (9.89)

280 (11.02)

AZ10 HTE SP 2.0

2.0 (0.079) 

20

250

280 (9.89)

290 (11.42)

AZ10 HTE SP 2.5

2.5 (0.098) 

25

300

290 (10.23)

300 (11.81)

AZ10 HTE PC with Pressure Container

AZ10 HTE PC 1.5

1.5 (0.059)

15

180 (6.36)

AZ10 HTE PC 1.8

1.8 (0.070)

18

250 (8.83)

AZ10 HTE PC 2.0

2.0 (0.079) 

20

250 (8.83)

AZ10 HTE PC 2.5

2.5 (0.098) 

25

190 (6.71)

2.5 (36)

2.5 (36)

300-400

(11.81-

15.75)

_

ANEST IWATA Europe S.r.l.

46, Corso Vigevano 
10155 Torino - Italy 
Tel. ++39 011 24 80 868
Fax ++39 011 22 74 406

www.anest-iwataeu.com

e-mail: [email protected]

Instruction Manual

AIR GUNSA s.r.l.

46, Corso Vigevano 
10155 Torino - Italy 
Tel. ++39 011 24 80 868
Fax ++39 011 22 74 406

Quality Air Spray Guns Since 1944

www.anest-iwataeu.com/airgunsa

Distributed by:

Recommended condition

Max. Pressure:

7.0 bar (100 PSI)

Max. Temperature:

Noise Level (LAeqT)

75.2 dB (A) AZ10 HTE SP

Atmosphere

5 ~ 40 °C

73.7 dB (A) AZ10 HTE PC

Air and fluid

5 ~ 43 °C

Spray conditions

Recommended condition in Tech. Specifications

Air connection

G 1/4”

Measuring point

1m backwards from gun, 1,6 m height

Model

Weight Fluid 

g (lbs)

Connection

AZ10 HTE SP 1/4”

480 (1.06)

G 1/4” M

AZ10 HTE SP 3/8”

480 (1.06)

G 3/8” M

AZ10 HTE SP AV 1/4”

490 (1.08)

G 1/4” M

AZ10 HTE SP AV 3/8”

490 (1.08)

G 3/8” M

AZ10 HTE PC

970 (2.13)

M16x1 F

SPRAY  GUN AZ10 HTE SP 1/4”- AZ10 HTE SP 3/8”

AZ10 HTE SP AV 1/4”- AZ10 HTE SP AV 3/8”- AZ10 HTE PC

Summary of Contents for AZ10

Page 1: ...t gun inlet when trigger is pulled and air flows 2 Paint viscosity 21 sec Ford cup 4 AZ10 HTE SP 54 sec Ford cup 4 AZ10 HTE PC Before use adjustment or maintenance it is important to read this instruction manual very carefully This manual must be stored in a safe place for any future reference that may be necessary GB Model Nozzle Air Cap 1 Atomizing 2 Fluid Air Pattern Orifice set Mark Air pressu...

Page 2: ...ring of cleaning liquid In order to release pressure first stop supply of compressed air fluid and thinner to spray gun Then remove fluid adj knob and pull fluid needle set towards you 4 Tip of fluid needle set has a sharp point Do not touch the tip of fluid needle during maintenance for the protection of the human body 1 Use in a well ventilated site by using spray booth If not poor ventilation c...

Page 3: ...29 to 44 PSI Recommended paint viscosity differs according to paint property and painting conditions 12 to 23 sec Ford cup 4 is recommendable Keep fluid output as small as possible to the extent that the job will not be hindered It will lead to better finishing with fine atomization Set the spray distance from the gun to the work piece as near as possible within the range of 100_200 mm 3 9_7 9 in ...

Page 4: ...h thinner and wipe out with waste cloth 2 Do not immerse the whole gun in thinner If done it can damage parts When cleaning never scratch any holes of air cap set and fluid nozzle and fluid needle set 3 Before disassembly fully clean fluid passages 3 During disassembly do not scratch seat section 1 Disassemble fluid nozzle 1 Remove fluid nozzle after removing fluid needle set or while keeping flui...