AIR CAP
1
NOZZLE HOLDER
2
NEEDLE PACKING NUT
4
TRIGGER STUD
5
COMPLETE AIR VALVE
7
AIR VALVE SHAFT
7-1
AIR VALVE SET
7-2
AIR VALVE SPRING
7-3
AIR VALVE SPRING SEAT
7-4
FLUID ADJUSTMENT GUIDE
7-5
PATTERN ADJUSTMENT
10
FLUID NEEDLE SPRING
12
FLUID NEEDLE ADJ. KNOB
13
FLUID NOZZLE
14
FLUID NEEDLE
15
TRIGGER
17
AIR NIPPLE
20
FLUID NIPPLE
24
AIR FLOW CONTROL VALVE
25
(AZ10 HTE SP AV/ AZ10 HTE PC)
PACKING SET
C
AIR CAP PACKING SET
D
NEEDLE PACKING SET (AZ10 HTE SP W)
F
1l Aluminium Pressure CUP PC 19 B
for AZ10 HTE PC
3
6
SPARE PARTS LIST
NOTE:
When ordering parts, specify gun’s model,
part name with ref.No. and marked No.of air cap
set, fluid nozzle and fluid needle.
SPARE PARTS LIST
Description
Ref. Part
4. If something goes wrong, immediately stop operation and find the cause. Do not use again until you have solved the
problem.
HOW TO CONNECT
1. Connect an air hose to air nipple tightly.
2. Connect an applicable cup to fluid nipple tightly.
3. Flush the gun fluid passage with a compatible solvent.
4. Pour paint into container, test spray and adjust fluid output as well as pattern width.
HOW TO OPERATE
Suggested air pressure is 2.0 to 3.0 bar (29 to 44 PSI)
Recommended paint viscosity differs according to paint property
and painting conditions. 12 to 23 sec. / Ford cup #4 is recommendable.
Keep fluid output as small as possible to the extent that the job will
not be hindered. It will lead to better finishing with fine atomization.
Set the spray distance from the gun to the work piece as near as
possible within the range of 100_200 mm (3.9_7.9 in).
The gun should be held so that it is perpendicular to the surface of the workpiece at all times. Then, the gun should move in a straight
and horizontal line. Arcing the gun causes uneven painting.
CAUTION
- Use clean air filtered through air dryer and air filter.
If not, dirty air can cause painting failure.
- When you use this gun for the first time after purchasing, adjust fluid needle packing set.
Slowly tighten fluid packing seat and loosen a bit when fluid needle set does not return
smoothly, and adjust so that fluid needle set smoothly moves.
- When use this gun for the first time after purchasing, clean fluid passages spraying thinner
and remove rust preventive oil.
If not, remaining preventive oil can cause painting failure such as fish eyes.
- Firmly fix hose or container to spray gun.
If not, disconnection of hose and drop of container can
cause bodily injury.
OTHER PRECAUTIONS
100.200 mm
3.9-7.9 in
AZ10 HTE PC CUP
PC 19 B
AZ10 HTE PC