background image

 

6) 

If the plug or outlet does get wet DO NOT UNPLUG THE CORD; Disconnect the fuse or 
circuit breaker supplying power to the pump, then unplug and examine for the presence of 
water in the outlet. 

7) 

DO NOT use the pump near volatile liquids such as gasoline, thinners, etc,. as this creates 
the possibility of an explosion. 

 

CAUTIONS FOR USE 

1) 

Close supervision is necessary when an air pump is used by or near children. 

2) 

This pump is intended for 

clean, dry air only

. DO NOT, under any circumstances, attempt 

operation with water or other liquids, otherwise pump may be damaged. 

3) 

The ambient operating temperature for this pump is between 41

(5

) and 104

(40

). 

Operation of pump in temperatures outside the recommended temperature range may result 
in malfunction or severely shortened service life. 

4) 

DO NOT block the air from being discharged. Air pumps must have sufficient room to allow 
for heat dissipation.   

5) 

Failure to observe cautions will cause the pump to automatically switch off until cool.   

 

 

 
 

6) 

Always unplug pump prior to servicing. Grasp plug to remove cord from outlet. DO NOT 
remove by pulling on power cord. 

7) 

DO NOT use the air pump for other than  its  intended use. The use of attachments not 
recommended or not sold by Sunlight Supply, Inc may cause an unsafe condition. 

8) 

DO NOT install pump where it will be exposed to weather. 

9) 

DO NOT store pump in temperatures below freezing. 

10) 

Ensure pump is securely mounted prior to operation. 

11) 

Read and observe all important markings on pump. 

12) 

Ensure that extension cords (if required) have the correct or higher rating (amperes or watts). 
Ensure cord is properly positioned to avoid tripping.

 

13) 

To avoid injury, DO NOT contact moving parts or hot parts. 

14) 

Always  unplug an appliance from an outlet  before  putting on or taking off parts,before 
cleaning and when not in use

 

 
 

DO NOT REMOVE PUMP CASING UNLESS UNIT IS DISCONNECTED 

FROM MAIN POWER SUPPLY. 

 

3

Summary of Contents for 15

Page 1: ...sor Operation Maintenance Manual IMPORTANT PLEASE READ THIS MANUAL COMPLETELY SAVE THIS MANUAL FOR FUTURE REFERENCE AND KEEP IN CLOSE PROXIMITY TO THE AIR PUMP Thank you for purchasing Air Force Pro Linear Air Pumps It is manufactured to the highest standards using quality materials Please follow all recommended maintenance operational and safety instructions and you will receive years of trouble ...

Page 2: ...hen retrieve it If the pump s electrical components get wet unplug the pump immediately 2 Carefully examine the air pump after installation It should NOT be plugged in if there is water present on any of the pumps parts 3 DO NOT operate if the cord or plug is damaged 4 DO NOT operate if the pump is malfunctioning dropped or damaged in any way 5 To prevent the plug or electrical outlet from getting...

Page 3: ... have sufficient room to allow for heat dissipation 5 Failure to observe cautions will cause the pump to automatically switch off until cool 6 Always unplug pump prior to servicing Grasp plug to remove cord from outlet DO NOT remove by pulling on power cord 7 DO NOT use the air pump for other than its intended use The use of attachments not recommended or not sold by Sunlight Supply Inc may cause ...

Page 4: ...electric shock Failure to follow these instructions can result in death fire or electrical shock When repair or replacement of the cord or plug is required do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman when the ground...

Page 5: ...ury or other serious injury It is your responsibility to operate this product at recommended duty pressure and ambient room temperature 2 For a permanently connected product This product must be connected to a grounded metallic permanent wiring system or an equipment grounding terminal or lead on the product Power Supply must conform to all required safety codes and be installed by a qualified ele...

Page 6: ...low these instructions can result in burns eye injury or other serious injury It is your responsibility to l Regularly inspect and make necessary repairs to product in order to maintain proper operation l Make sure that pressure is released from product before starting maintenance l NEVER add oil to this oil less compressor Check intake filter after first 500 hours of operation Clean filter and de...

Page 7: ... diaphragm off its place E Replace a new one by mounting the rubber studs into their position F Press the rim of the diaphragm into the ring G Secure the magnet with a new u nut and screw and put the diaphragm housing back with the four screws on Replacement part Information Model Diaphragm Service kit Air Force Pro 15 Part No 746500 Part No 746530 Figure 1 Figure 2 IMPORTANT To open upper enclosu...

Page 8: ...ROMAGNET 2 3 CHECK VALVE 4 4 WIRE STOPPER 1 5 U SHAPED COIL FRAME 1 6 VIBRATION CONTROL RUBBER 4 7 ACTIVATING ARM 1 8 DIAPHRAGM 2 9 DIAPHRAGM FRAME 2 10 U NUT 2 11 DIAPHRAGM HOUSING 2 12 L TUBE 2 13 STEEL PLATE 1 14 GASKET 1 15 LOWER HOUSING 1 16 RUBBER FEET 4 17 POWER CORD 1 Product View and Parts List 8 ...

Page 9: ...ct to change without notice Performance Allowance 5 Dimensions mm Performance Curves DB15 0 5 10 15 20 25 30 35 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746500 110 120 60 0 43 20 26 dBA 20 80 10 o C 2 54 kg 40 Product Specifications 9 ...

Page 10: ...re 3 C Remove the u nut in the center of diaphragm D Take the diaphragm off its place E Replace a new one by mounting the rubber studs into their position F Press the rim of the diaphragm into the ring G Secure the magnet with a new u nut and screw and put the diaphragm housing back with the four screws on Replacement part information Model Type Diaphragm service kit Air filter service kit Air For...

Page 11: ...CTROMAGNET 2 8 WIRE STOPPER 1 9 U SHAPED COIL FRAME 1 10 VIBRATION CONTROL RUBBER 4 11 ACTIVATING ARM 1 12 DIAPHRAGM 2 13 DIAPHRAGM FRAME 2 14 U NUT 2 15 CHECK VALVE 4 16 L TUBE 2 17 DIAPHRAGM HOUSING 2 18 CHAMBER SEAL ROUND 2 19 CHAMBER SEAL OVAL 2 20 SIDE COVER STEEL 2 21 CORD PROTECTOR 1 22 STEEL PLATE 1 23 GASKET 1 24 LOWER HOUSING 1 25 RUBBER FEET 4 26 POWER CORD 1 Product View and Parts List...

Page 12: ...ject to change without notice Allowance 5 Dimensions mm Part No Voltage VAC Frequency HZ AMP A WATT W 746505 110 120 60 1 1 45 Performance Curves DBM40 0 10 20 30 40 50 60 70 80 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz 46 dBA 20 80 20 o C 6 09 kg 40 40 40 Product Specifications 12 ...

Page 13: ...ubject to change without notice Allowance 5 Dimensions mm Performance Curves DBM60 0 20 40 60 80 100 120 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746510 110 120 60 1 7 63 47 dBA 20 80 10 o C 6 99 kg 40 60 60 Product Specifications 13 ...

Page 14: ...to change without notice Allowance 5 Dimensions mm Performance Curves DBM80 0 20 40 60 80 100 120 140 0 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 5 0 55 Pressure kg cm2 Q L Min 110 120V 60Hz 220 240V 50Hz Part No Voltage VAC Frequency HZ AMP A WATT W 746515 110 120 60 1 9 84 51 dBA 20 80 10 o C 7 05 kg 40 80 80 Product Specifications 14 ...

Page 15: ...LITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighboring areas While we attempt to assure that the products comply with such codes it cannot guarantee compliance and cannot be responsible for how the product is installed or used Before purchase and use of a product review the pr...

Page 16: ...Exclusively distributed by ...

Reviews: