Wiring to sub station should be 2-conductor shielded cable.
Wire distance from IPW-1A to IE series sub station:
22AWG = 387 feet, 18AWG = 980 feet
RESET
RS-232
STATUS
SUB
PT-1211C
SUB
1
2
Audio Only Door
IE Series sub station
LAN
PWR
POWER
IN0 IN1 NO C NC
PT
Note:
Contact rated at 30V AC/DC, 1.0A
*
5. Wiring & Terminal Definitions
IN0 IN1 NO C NC
T
*Normally Closed dry contact
*Common
*Normally Open dry contact
Input ground
Input 1 (sensor input)
Input 0 (external call button input)
* The dry contact can be used for door
release or an alarm output.
1. Load the software onto the PC to be used as a master station. Insert CD (included with IPW-1A)
or download the latest version from the Aiphone website (www.aiphone.com).
2. Install the CommuniCenter software by following the on-screen prompts, or by executing
“
setup.exe
” to begin the installation process.
3. Any IPW-1A adaptors within the broadcast domain should automatically appear on the sub
station list on the right. Refer to Section 8 of this user guide for software functionality and
configuration information. Refer to Section 12 of this user guide for hardware configuration.
4. Software Installation
T
Pg. 4