background image

TROUBLESHOOTING TIPS

Fault / Display 

Cause 

Solutions 

No output voltage, buzzer sounds 
continuously

 

 

Low input DC voltage

 

Recharge or replace the battery

 

Do not use it when the battery is charging. 
Check the rated voltage of the battery and 
make sure it is in within the range of the input 
voltage. 

High input DC voltage

 

 

Overload

 

Reduce the load.

 

Over temperature

 

Cut off the load and let cool for 10 to  30 
minutes. Restart it after it resumes to normal 
temperature

The load is too large, reduce 

the total load to the range of rated power. 
Avoid blocking the vent and improve the 
ventilation condition

Reduce the ambient 

temperature

.

 

 

No output voltage 

The switch is off 

Turn on the power switch. 

Poor cable connection 

Check the cables and make sure they are 
tightly connected

.

  

Incorrect output voltage

 

RMS Multimeter measurement error

 

Use a true RMS multimeter to measure

,

 such 

as 

model FLUKE 177/179.

  

The 

battery 

power 

of 

RMS Multimeter is low.

 

Try to maintain the input voltage in the 
range of rated power.  

The input voltage 

may be too high or too low. 

Change the battery of the multimeter then test 
again

.

 

 

Cannot drive the load 

Load power is too large

,

 or the 

actual power of the appliance 
exceeds nominal power

.

 

Reduce  the  load

,

 or  turn  on  the 

appliance first

,

 then turn on the inverter.

 

The starting power is larger than 
rated power (such as motor). 

The internal inverter

 

soft-start circuit will buffer 

starting the appliance.

 

 

8

Summary of Contents for PWRI150012120S

Page 1: ...DC TO AC PURE SINE POWER INVERTER PWRI150012120S INSTRUCTION MANUAL ETL Listed to UL 458 and CSA 22 2 NO 107 1 1...

Page 2: ...e negative ground 5 Do not disassemble the unit it may cause fire or electric shock 6 This device should only be serviced by a qualified technician This item does not have any serviceable parts 7 Prev...

Page 3: ...not be built into this product but must be supplied by operator Guard against electric shock Do not open the metal case risk of electric shock INVERTER FEATURES Three outlets USB Port LED protect indi...

Page 4: ...e electrical equipment In this case the battery will cause the inverter to go into under voltage protection because of the load put on the battery A simple way to calculate the load or amps required f...

Page 5: ...mage the inverter and void warranty 3 If connecting to a breaker panel do NOT neutral ground bond the panel USING THE POWER INVERTER 1 Check the output voltage and capacity of the battery The battery...

Page 6: ...voltage is lower than 9 5V 19V 38V The buzzer will whistle continuously and the green light is off red light is on Please turn off the inverter and use it after recharging the battery 3 Over voltage p...

Page 7: ...f UL 458 is that all AC inverters pass a High Voltage Dielectric Withstand Test commonly called the Hi Pot Test The voltage applied to the control is usually equal to 1 000 volts plus two times the li...

Page 8: ...ambient temperature No output voltage The switch is off Turn on the power switch Poor cable connection Check the cables and make sure they are tightly connected Incorrect output voltage RMS Multimeter...

Page 9: ...SPECIFICATIONS 9...

Page 10: ...ar purpose In no event shall AIMS be liable for indirect special or consequential damages This warranty only applies to AIMS Power branded products All other name brand products are warranted by and a...

Reviews: