background image

13. The power inverter will output the same AC power as utility power, please treat

the AC outlets as carefully as you would your home AC outlets. Do not put
anything other than an electrical appliance into the output terminal.  It may cause
shock or fire.

14. Disconnect the battery and inverter when not in use.

Note:

 Performance of this unit may vary depending on the available battery power or 

appliance wattage. 

Warning:  The  warnings,  cautions,  and  instructions  discussed  in  this  instruction 
manual cannot cover all possible conditions and situations that may occur. It must 
be understood by the operator that common sense and caution are factors which 
cannot be built into this product, but must be supplied by operator. Guard against 
electric shock. Do not open the metal case; risk of electric shock. 

INVERTER FEATURES

Three 

outlets

USB Port

LED protect indicator

LED power indicator

Easy push on/off switch

Remote port for on/off remote switch (optional)

Thermally controlled cooling fan

Low battery voltage warning/shutdown

High input voltage protection with automatic shutdown

Over load indicator

Short circuit protection

AC output short circuit protection

INSTALLATION

Ensure there is enough space for the installation, and the location should be meet 
the following requirements: 

1.

Water should not access the inverter.

2.

The ambient temperature should be 32~104°F, and the preferred temperature is

50-

77°F. The lower the better in this range of ambient temperature.

3.

Do not mount the inverter upside down.

3

Summary of Contents for PWRI150012120S

Page 1: ...DC TO AC PURE SINE POWER INVERTER PWRI150012120S INSTRUCTION MANUAL ETL Listed to UL 458 and CSA 22 2 NO 107 1 1...

Page 2: ...e negative ground 5 Do not disassemble the unit it may cause fire or electric shock 6 This device should only be serviced by a qualified technician This item does not have any serviceable parts 7 Prev...

Page 3: ...not be built into this product but must be supplied by operator Guard against electric shock Do not open the metal case risk of electric shock INVERTER FEATURES Three outlets USB Port LED protect indi...

Page 4: ...e electrical equipment In this case the battery will cause the inverter to go into under voltage protection because of the load put on the battery A simple way to calculate the load or amps required f...

Page 5: ...mage the inverter and void warranty 3 If connecting to a breaker panel do NOT neutral ground bond the panel USING THE POWER INVERTER 1 Check the output voltage and capacity of the battery The battery...

Page 6: ...voltage is lower than 9 5V 19V 38V The buzzer will whistle continuously and the green light is off red light is on Please turn off the inverter and use it after recharging the battery 3 Over voltage p...

Page 7: ...f UL 458 is that all AC inverters pass a High Voltage Dielectric Withstand Test commonly called the Hi Pot Test The voltage applied to the control is usually equal to 1 000 volts plus two times the li...

Page 8: ...ambient temperature No output voltage The switch is off Turn on the power switch Poor cable connection Check the cables and make sure they are tightly connected Incorrect output voltage RMS Multimeter...

Page 9: ...SPECIFICATIONS 9...

Page 10: ...ar purpose In no event shall AIMS be liable for indirect special or consequential damages This warranty only applies to AIMS Power branded products All other name brand products are warranted by and a...