Pressure Value Setting
Pressure value setting without using Automatic Setting Function
(1)
In the case of Shut-off Tool (TM)
・
Connect Tool in the first place
・
Touch
key for more than 3 seconds and start “MENU” screen.
・
Set TOOL to SHUT-OFF TYPE on “SET UP” screen.
・
Then, select “SENSOR”. Select “NO DISPLAY” when a private pressure sensor will be
used and select “DISPLAY” when a digital pressure sensor will be used.
・
Return to “MENU” screen by touching
key, and touch
key again to return to
the measurement screen.
・
Read Free Running, Blow and Shut-off pressure values on the measurement screen.
・
Enter a midrange value between Free Running and Blow pressures in the “LEVER ON”
column on the “SET UP” screen.
・
Enter a midrange value between Blow and Shut-off pressures in the “SHUT-OFF”
column.
・
Check operating conditions on the measurement screen.
(2)
In the case of TM Type Tool
・
Connect Tool in the first place.
・
Touch
key for more than 3 seconds and start “MENU” screen.
・
Set TOOL to TM TYPE on “SET UP” screen.
・
Then, select “SENSOR”.
・
Return to “MENU” screen by touching
key, and touch
key again to return to
the measurement screen.
・
Read Free Running and Blow pressure values on the measurement screen.
・
Enter a value not exceeding Free Running pressure in LEVER ON column on “SET UP”
screen.
・
Enter a midrange value between Free Running and Blow pressures in the “BLOW
START” column.
・
Check operating conditions on the measurement screen.
(3)
In the case of Standard Tool
・
Connect Tool in the first place.
・
Touch
key for more than 3 seconds and start “MENU” screen.
・
Set TOOL to NON-SHUT TYPE on “SET UP” screen.
・
Then, select “SENSOR”.
・
Return to “MENU” screen by touching
key, and touch
key again to return to
the measurement screen.
・
Read Tool Stop, Free Running and Blow pressure values on the measurement screen.
・
Enter a midrange value between Tool Stop and Blow pressures in the “LEVER ON”
column on “SET UP” screen.
・
Enter a midrange value between Free Running and Blow pressures in the “BLOW
START” column.
・
Check operating conditions on the measurement screen.