25
AUTOMATIC SET UP
(automatic setting)
This Automatic Set Up function performs automatic pressure setting by utilizing the pressure
variation obtained through Tool free running and practical fastening operation.
(1)
Tool Selection
①
Select Tool you will use and press
key.
(2)
Measurement of Pressure at Free Running
①
Run your Tool for 2~3 seconds under no-load, and then release the lever.
(
Run your Tool with the socket and bit removed from Tool end.
)
②
The buzzer sounds when the controller has read pressure value, and the measured pressure
value will be on display.
③
Run your Tool again under no-load when re-measurement is necessary.
④
Press
key when pressure value is obtained normally.
(3)
Measurement of Blow Pressure / Shut-off Pressure (in the case of SHUT-OFF selection)
①
Start fastening operation with a bolt seated. In the case that Shut-off Tool is in use,
perform fastening operation until shut-off.
②
The buzzer sounds when the controller has read pressure values, and the measured
pressure values will be on display.
③
Return to
①
when re-measurement is necessary, and press
key when pressure
values are obtained normally.
(4)
Set Value Display
①
Pressing
key will call up the previous screen (Blow/Shut-off Pressure Measurement).
②
Pressing
key will call up MENU screen upon rewriting the setting values.
③
You may perform re-measurement also at this stage by repeating fastening operation.
* AUTOMATIC SET UP *
Air Pat Free Running
0.00 Mpa
* AUTOMATIC SET UP *
■SHUT-OFF
TM TYPE
NON-SHUT TYPE
* AUTOMATIC SET UP *
Air P‘s during Blows
0.00Mpa~0.00Mpa
0.00Mpa
Blow Pressure Range
Shut-off Pressure
LEVER ON : 0.** Mpa
SHUT-OFF : 0.** Mpa
PULSE LV : 0.*** Mpa
1-PULSE : **** msec