W. SEL. TIMING (WORK No. switching timing)
Initial Setting
: NO (without timing
)
・
This setting is common among WORK No. 1~4.
Particulars
NO (without timing)
・
WORK No. switching will take effect immediately after WORK SELECT input condition has been
changed.
YES (with timing
)
・
The following timings will be interposed at the time of WORK No. switching.
①
At the time of Front Panel RESET key input
②
At the time of RESET terminal input
③
At the time when COUNT OK lamp is turned off.
ERROR (refastening at the time of fastening error)
Initial Setting
: REFASTENING (fastening NOK will be cleared upon refastening operation
start)
・
Select refastening at the occasion of fastening errors:
・
This setting is common among WORK No. 1~4.
Particulars
REFASTENING (Fastening NOK clearing at refastening operation start)
・
Fastening error will be cleared at the time of refastening operation start.
NO RE-F (refastening will not be accepted until Fastening NOK RESET)
・
When a fastening error (initial error/cycle error) occurs under this setting, the next fastening
signals cannot be accepted until such error condition has been cleared by inputting Fastening
NOK RESET. When TM Type Tool or Standard Tool is in use, VALVE ON status will be
kept ON until such error condition has been cleared, and the next fastening operation cannot
be accepted without error cancellation.
CHECK BZ VOL. (Fastening Operation Check Buzzer Sound)
Initial Value
: 5
Setting Range
: 0~5
・
This buzzer sounds to give operators a count-down signal at the time of Fastening OK or QL
input.
0: no sound
1: low-volume~5: high-volume
・
The buzzer will turn ON for 1-pulse duration at count-down and turn ON for 2-pulse duration at
Count OK.
・
This setting is common among WORK No. 1~4.
・
Be sure to set to Level 5 when you use the low-tone buzzer.
NOK BZ VOL. (NOK Buzzer Sound)
Initial Value
: 5
Setting Range
: 0~5
・
This buzzer sounds to give operators Fastening NOK or Count NOK signals.
0: no sound
1: low-volume~5: high-volume
・
This setting is common among WORK No. 1~4.
・
Be sure to set to Level 5 when you use the low-tone buzzer.