10
Handling Method
Parts
Ambient temperature: 0
– 40
°
C (32
– 104
°
F).
Rotating speed change: 3-steps
Slow speed: 500 rpm
– 1,000 rpm for socket-bolt entry or temporary
tightening
Model
Motor
Voltage
DC
Approx.
Free
Speed
(rpm)
Bolt capacity
(nominal
size)
(mm)
Approx.
Torque
Range*
(Nm)
Weight with
battery
pack
(kg)
Approx.
Overall
Length
(mm)
Sq Dr/
Hex.
size
(mm)
BP-T40
10.8 V
3,300
M5
4.5~8
1.4
197
9.5 SQ
BP-T40D
200
6.35 Hex
BP-T50
3,900
M6~M8
7~15
197
9.5 SQ
BP-T50D
6.5~13
200
6.35 Hex
BP-T60
14.4
4,800
M8
13~26
1.6
202
9.5 SQ
BP-T60D
205
6.35 Hex
*Torque range for reference only
Allen key for torque
adjustment
Trigger
Reverse lever
Battery Pack
Shut-off information LED
Summary of Contents for BP-T40