Alarms and digital output configuration
10.1.4 Parameters
10.1.5 Alarm LEDs digital output and Shift Lights
Press
"Parameters"
tab to set the lap detection.
Please make sure that optical beacon is enabled. If you bought a GPS08 Module you can set
"GPS Beacon"
.
This last requires the track width.
Optical Beacon requires you to insert a time during which the system does not record
additional lap signals.
Click
“Shift Lights and Alarms”
tab to manage Shift Light LEDs, Alarm LEDs and the
Digital Output
At the very first configuration the system asks you to configure an alarm showing you
this panel.
Here you can define the event the system
has to check and the effect of that event.
1) Fill the DESCRIPTION field, in order to
easily identify the event in the future.
2) Describe the Alarm: it can be a single
event like "water temperature higher
than 100°C" or a combination of events,
like in the example: "water temperature
is higher than 100°C" and "RPM is higher
than 6000”.
3) Describe what to do when an alarm
arises. MXS Strada can:
n
Turn a LED on: you have to select
the colour and the behaviour: in the
example a red led (LED 1) starts
blinking continuously
n
Turn the digital output on: you have
to decide whether closing to
ground or open the circuit
4) finally, you have to decide if
keeping the LED on:
n
Until the condition remains ON
n
Until the power is turned OFF
n
Until the driver presses a pushbutton
Summary of Contents for MXS STRADA