Software Library Reference Manual for VME 429
133
Section 6 - Receiver Functions
6.8 Api429CmdRxLabRead
P
P
r
r
o
o
t
t
o
o
t
t
y
y
p
p
e
e
:
:
AiUInt8 Api429CmdRxLabRead( AiUInt8 b_Module, AiUInt8 b_Chn, AiUInt8 b_Label,
AiUInt8 b_Sdi, AiUInt8 b_LabCntIni,
AiUInt16 *pw_LabIx, AiUInt32 *pl_LabCnt,
AiUInt32 *pl_LabErr );
D
D
r
r
i
i
v
v
e
e
r
r
C
C
o
o
m
m
m
m
a
a
n
n
d
d
:
:
API429_RX_LABEL_READ (0x96)
P
P
u
u
r
r
p
p
o
o
s
s
e
e
:
:
This function is utilized to read the execution status of a specific label on the
selected API429 receiver channel. The label counter mode must be enabled.
Note:
The transfer counter will be incremented only if "px_Cmd
Î
lcen" in the
"Api429CmdReset" command is set to 1!
I
I
n
n
p
p
u
u
t
t
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
C
C
h
h
n
n
Channel Number
Value Description
1..32
API429 receiver channel number
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
L
L
a
a
b
b
e
e
l
l
Value Description
0..255
Label Number
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
S
S
d
d
i
i
Value Description
0..3
SDI Number
4
Special SDI-Handling:
All received data will be stored in one buffer.
The latest received data will be stored in the
buffer.
Note:
Only valid if SDI sorted in command 'Api429CmdReset' is enabled!
A
A
i
i
U
U
I
I
n
n
t
t
8
8
b
b
_
_
L
L
a
a
b
b
C
C
n
n
t
t
I
I
n
n
i
i
Value Description
0
Do not initialize counter after execution (MSG /
ERRORS)
1
Initialize counter after execution
Summary of Contents for AMC429
Page 2: ......