2021-10-28
REV2.0
Flexible parts feeder system
AIM company
l
www.aim-fa.com
6
What to do in an emergency
Use the power off button on the side of the AIVE. Press the emergency stop button
(Yellow background/Red push button) on all robots being used together. This
button de-energizes the feeder and follows the
company’s
or
organization’s
internal
procedures in case of an emergency. In case of fire, CO2 is used to extinguish the
fire.
1-3) Safety
Safety function
Motor temperature sensor
It is set at 36
℃
, and when it exceeds this, an alarm code is displayed and the
power to the motor is cut off.
Peak limitation
:
Forced stop when the motor maximum current time setting time exceeds 4000mA, 1Sec.
Motor stuck _temperature :
If the motor does not move due to external force, forced stop when the set time is exceeded.