background image

2

4.1 MT9207 178-mm (7-inch),

MT9214 356-mm (14-inch) and
MT9224 610-mm (24-inch)
Column Mounts

SAFETY PRECAUTIONS

The exclamation point within an equilateral triangle is

intended to alert the user to presence of important

operating and maintenance (servicing) instructions in

the literature accompanying the appliance.

SECURITE

Le point d'exclamation à l'intérieur d'un triangle

équilatéral avertit l'utilisateur de la présence d'in-

structions importantes d'utilisation et de mainte-

nance dans la documentation accompagnant l'ap-

pareil.

SICHERHEITSVORKENHRUNGEN

Das Ausrufezeichen in dem gleichseitigen Dreieck ist

dazu da, den Benutzer auf wich-tige Inbetriebnahme-

und Instandhaltungs-vorschriften hinzuweisen, die

dem Gerät in Form einer Broschüre beigelegt sind.

PRECAUCIONES DE SEGURIDAD

El símbolo de exclamación dentro de un triángulo

equilátero, se muestra con el objetivo de alertar al

ususario de que instrucciones de operación y man-

tenimiento importantes acompañan al equipo.

Top

Side View

1. Determine a secure mounting location, either for a

pedestal (floor) mounted installation or for an overhead

(ceiling) mounted installation.

2.

Caution

:

a. For a secure mounting installation, bolts should

extend through the mounting surface and be secured

with nuts, washers, and lock washers on the opposite

side.

b. If studs are used, they should either be anchored in

concrete or welded to a steel backer plate.

c. If the MT9207, MT9214 or MT9224 is mounted to

wood or a blind structure (with no access to the

rear) in a ceiling, make certain that the mounting fas-

teners have a

minimum

pull-out strength of 600

pounds.

1

UNPACKING

Unpack carefully.This is mechanical equipment and should be

handled carefully.
Check for the following items:
• Verify the unit model number.

• Installation and Operating Instructions.
If an item appears to have been damaged in shipment, replace

it properly in its carton and notify the shipper. If any items are

missing, notify Aigis Mechtronics.
The shipping carton is the safest container in which the unit

may be transported. Save it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer should

contact Aigis Mechtronics.

3

DESCRIPTION

These versatile indoor/outdoor mounts accommodate fixed

cameras, housings, pan/tilts, and scanners.

4

INSTALLATION

See

SPECIFICATIONS

for the maximum rated load of

mount.

Mounting Hardware: Not furnished.

Note

:The use of stainless steel or zinc-plated fasteners is

recommended.

WARNING

:The maximum rated load is reduced to 45.3

kg (100 lb) when mounted beneath a ceiling.

3. Locate and drill four mounting holes using the end flanges

as a template.

4. Using four bolts (or studs) with nuts, washers, and lock

washers, fasten the MT9207,MT9214 or MT9224 to its

mounting location and tighten all nuts securely.

Note

:The

minimum

diameter bolt (or stud) required is

10 mm (3/8 in).

5. To mount the MT9227 Adjustable Head Bracket:

a. Use the mounting hole which is located in the center

of the MT9207, MT9214 or MT9224 mounting plate.

This mounting hole is threaded to receive a 1/4-20

bolt.

b. Insert a 1/4-20 hex head machine bolt with washer

and lock washer through the MT9227 base plate and

into the threaded insert on either end flange of the

MT9207, MT9214 or MT9224.

6. To mount the MT9237 Heavy Duty Adjustable Head

Bracket:

a. Line up the holes in the corners of the MT9237 base

plate with the slots in the mounting flange.

b. Insert a 3/8-16 x 1” hex bolt through the base plate

and mounting flange, using a 3/8” flat washer and a

3/8” spiral lock washer under the head of the bolt.

c. From the underside of the mounting flange, use a

3/8” flat washer and a 3/8-16 hex nut to secure the

MT9237 to the mounting flange.

Summary of Contents for MT9207

Page 1: ...00 76 3 00 210 8 25 6 x 13 0 50 32 1 25 7 2 I N S T A L L A T I O N A N D O P E R A T I N G I N S T R U C T I O N S W W W A I G I S M E C H C O M INDOOR OUTDOOR HEAVY DUTY MOUNTS MT9207 MT9214 MT9216...

Page 2: ...unit model number Installation and Operating Instructions If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper If any items are missing notify...

Page 3: ...a flat washer and a 3 8 flat washer and 3 8 sprial lock washer under the head of the bolt c From the underside of the flange bracket use a 3 8 flat washer and 3 8 16 hex nut to secure the MT9237 to t...

Page 4: ...a 1 4 20 hex head machine bolt through the adjustable head and into the threaded insert in the wall mount The bolt should be 20 mm 3 4 in long A lock washer and a flat washer must be used under the he...

Page 5: ...Mount wall or dome mount as instructed in the accompanying instructions 6 x Customer Supplied Bolt MT9216 or MT9222 Wall Mount 5 x Threaded Pemstud Pre Assembled 5 x 3 8 Plain Washer 5 x 3 8 16 Lock...

Page 6: ...ttom View of Mounting Flanges Top and Bottom Side View Dia 7 0 178 7 0 MT9224 B A ing 1 4 20 Top and Bottom Dia mm in 178 7 0 76 3 0 olt Circle View S ame s Wall Mounts Top and Bottom View of Mount Fl...

Page 7: ...5 mm in 1 3 0 5 Dia 3 Places 16 5 6 5 D Side View Tilt Adjust Bottom View Base Plate x 2 76 3 0 63 2 5 24 1 0 127 5 0 114 4 5 152 6 0 76 3 0 8 6 0 34 Dia Ctrd 7 1 0 28 1 Hole Dia 2 Slots x 11 9 0 47 L...

Page 8: ...d 5 3 8 16 lock nuts Finish Light Gray Powder Coat Weight 2 1 kg 4 6 lb 5 5 MT9226 Corner Bracket Maximum Rated Load 45 3 kg 200 lb Mounting Hardware Not furnished Finish Light Gray Powder Coat Weight...