background image

3

This label may appear on the bottom of the unit due to space limitations.

The lightning flash with an arrowhead symbol within an equilateral
triangle is intended to alert the user to the presence of uninsulated
"dangerous voltage" within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock to
persons.

The exclamation point within an equilateral triangle is intended to
alert the user to presence of important operating and maintenance
(servicing) instructions in the literature accompanying the
appliance.

Attention:

Installation should be performed by qualified service

personnel only in accordance with the National Electrical Code
or applicable local codes.

24 VAC  Units:

Do Not Exceed 30 VAC Input.Voltage applied to the unit’s

power input should not exceed 30VAC. Normal input voltage is 24 VAC. User
supplied wiring from 24 VAC supply to unit must be in compliance with
electrical codes (Class 2 power levels). Do not ground 24 VAC supply at
power supply terminals or at unit’s power supply terminals.

WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO
NOT EXPOSE UNITS TO RAIN OR MOISTURE.

SAFETY PRECAUTIONS

CAUTION:TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT OPEN COVERS. NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.

1

UNPACKING

This electronic equipment should be unpacked and
handled carefully.

If an item appears to have been damaged in
shipment, replace it properly in its carton and notify
the shipper. If any items are missing, notify Aigis
Mechtronics. The shipping carton is the safest
container in which the unit may be transported. Save
it for possible future use.

2

SERVICE

If the unit ever needs repair service, the customer
should contact Aigis Mechtronics for return
authorization and shipping instructions.

3

CARE AND MAINTENANCE

There are no moving parts in this unit. Regularly
scheduled maintenance will help prolong the
operational life of this unit. Clean the viewing window
as needed with a mild, nonabrasive detergent in water
and a soft cloth.

4

DESCRIPTION

The IND6 Series of environmental housings are
attractive aluminum housings and sunshield with a
polycarbonate dome bubble designed for outdoor
installations. 

Summary of Contents for IND6 Series

Page 1: ...9 35 237 5 8 86 225 0 8 58 218 0 4 33 110 0 3 31 84 0 2 36 60 0 5 51 140 0 6 30 160 0 0 39 10 0 11 81 300 0 9 35 37 5 8 86 225 0 4 33 110 0 3 31 84 0 2 36 60 0 5 51 140 0 6 30 160 0 0 39 10 0 I N S T...

Page 2: ...mpletion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power sour...

Page 3: ...terminals or at unit s power supply terminals WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE UNITS TO RAIN OR MOISTURE SAFETY PRECAUTIONS CAUTION TO REDUCETHE RISK OF ELECTRICAL SHOCK DO NOT OP...

Page 4: ...hole Refer to Figure 1C 3 Install the appropriate anchors or threaded inserts at the locations marked in step 1 4 Connecting Low Voltage Power The wiring harness has a BNC connector to accept video co...

Page 5: ...gure 2 Figure 5 Figure 6 Figure 7 Figure 3 Figure 4 Slot 1 Set the camera to the desired position by adjusting the pivot points This camera module can be adjusted both vertically and horizontally The...

Page 6: ...djustments to the lens and camera replace the liner and trim ring bubble Camera adjustment points Camera Shown at a 90 Tilt Camera Shown at a 0 Tilt Figure 5 Camera Position Adjustments Figure 9 Camer...

Page 7: ...e lock is on the backlight compensation is off and the white balance is on Figure 10 Camera Assembly CAMERA MODULE ADJUSTMENTS AND CONNECTIONS A Power Block 1 Supply 2 Secondary GND Do not connect 3 S...

Page 8: ...300 0 0 39 10 0 9 35 237 5 8 86 225 0 8 58 218 0 12 05 306 Dimensional Outlines 100 0178 001 AIG 09 06 Printed in U S A 2006 Aigis Mechtronics 1124 Louise Road Winston Salem NC 27107 5450 Tel 336 785...

Reviews: