13.

 

INDIVIDUAL/GROUP

 

PAGER

 

ID’s

 

 

Each

 

Pager

 

can

 

have

 

an

 

individual

 

code

 

so

 

the

 

user

 

can

 

be

 

notified

 

direct

 

from

 

a

 

Maxpage

 

Terminal

 

plus

 

group

 

codes

 

so

 

they

 

can

 

be

 

notified

 

of

 

alarm

 

calls

 

in

 

their

 

zone

 

direct

 

from

 

the

 

Nursecall

 

system.

 

 

Ward

 

1

 

Pager

 

1

  

ID

 

 

0000

101

 

Individual

 

call

 

to

 

Pager

 

(e.g.

 

from

 

Maxpage

 

Terminal)

 

Group

 

1

 

0000

100

 

General

 

calls

 

for

 

Ward

 

1

 

Group

 

2

 

0000

161

 

Emergency

 

calls

 

for

 

Wards

 

1

 

&

 

2

 

 

Pager

 

2

  

ID

 

 

0000

102

 

Individual

 

call

 

to

 

Pager

 

(e.g.

 

from

 

Maxpage

 

Terminal)

 

 

 

Group

 

1

 

0000

100

 

General

 

calls

 

for

 

Ward

 

1

 

 

 

Group

 

2

 

0000

161

 

Emergency

 

calls

 

for

 

Wards

 

1

 

&

 

2

 

 

Ward

 

2

 

Pager

 

1

  

ID

 

 

0000

201

 

Individual

 

call

 

to

 

Pager

 

(e.g.

 

from

 

Maxpage

 

Terminal)

 

 

 

Group

 

1

 

0000

200

 

General

 

calls

 

for

 

Ward

 

2

 

 

 

Group

 

2

 

0000

161

 

Emergency

 

calls

 

for

 

Wards

 

1

 

&

 

2

 

 

Pager

 

2

  

ID

 

 

0000

202

 

Individual

 

call

 

to

 

Pager

 

(e.g.

 

from

 

Maxpage

 

Terminal)

 

 

 

Group

 

1

 

0000

200

 

General

 

calls

 

for

 

Ward

 

2

 

 

 

Group

 

2

 

0000

161

 

Emergency

 

calls

 

for

 

Wards

 

1

 

&

 

2

 

 

The

 

pagers

 

in

 

each

 

ward

 

have

 

individual

 

codes

 

so

 

they

 

can

 

be

 

called

 

individually

 

from

 

the

 

Maxpage

 

Terminal,

 

e.g.

 

to

 

call

 

pager

 

1

 

in

 

ward

 

1

 

you

 

would

 

call

 

0000101.

 

Both

 

pagers

 

in

 

ward

 

1

 

also

 

have

 

an

 

ID

 

0000100

 

so

 

if

 

a

 

call

 

was

 

made

 

to

 

that

 

number

 

both

 

pagers

 

would

 

be

 

notified,

 

similarly

 

with

 

both

 

pagers

 

in

 

ward

 

2

 

with

 

ID

 

0000200.

 

If

 

an

 

emergency

 

call

 

is

 

made

 

to

 

ID

 

0000161

 

then

 

all

 

4

 

pagers

 

would

 

be

 

notified.

  

  

The

 

Touchsafe

 

Pro

 

Nursecall

 

system

 

can

 

be

 

setup

 

with

 

different

 

call

 

types

 

to

 

different

 

Pager

 

ID’s

 

on

 

a

 

per

 

zone

 

basis

 

 

refer

 

to

 

the

 

Astra

 

Transmitter/Maxpage

 

Terminal

 

manuals.

 

 
 

14.

 

MANUAL

 

PROGRAMMING

  

 

J25

 

Pagers

 

are

 

factory

 

programmed

 

with

 

ID1:

 

ON

 

1234567

,

 

this

 

can

 

be

 

changed

 

and

 

ID’s

 

2

6

 

can

 

be

 

set

 

following

 

the

 

procedure

 

below;

  

 

Remove

 

the

 

battery

 

from

 

the

 

Pager,

 

press

 

and

 

hold

 

the

         

READ

 

key

 

and

 

re

insert

 

the

 

battery.

 

Keep

 

the

         

READ

 

key

 

pressed

 

until

 

MNL

 

PROGRAM

 

is

 

displayed

 

on

 

the

 

screen

 

then

 

release.

 

Press

 

the

         

READ

 

key

 

and

 

the

 

display

 

will

 

change

 

to

 

[0000]

 

with

 

the

 

first

 

zero

 

flashing.

 

You

 

need

 

to

 

Enter

 

0200;

 

press

 

the

         

READ

 

key

 

until

 

the

 

second

 

digit

 

flashes.

 

Press

 

the

 

 

key

 

twice

 

to

 

display

 

a

 

2

 

then

 

press

 

the

        

READ

 

key

 

twice

 

to

 

enter

 

programming

 

mode.

 

Press

 

the

         

READ

 

key

 

again

 

and

 

ID1

 

will

 

be

 

displayed

 

e.g.

 

ID1

 

ON

 

1234567

  

Press

 

the

         

READ

 

key

 

until

 

the

 

required

 

digit

 

flashes

 

then

 

use

 

the

 

 

key

 

until

 

the

 

display

 

shows

 

the

 

required

 

number,

 

press

 

the

         

READ

 

key

 

to

 

enter

 

and

 

repeat

 

for

 

each

 

digit.

 

Repeat

 

to

 

enter

 

ID2

 

to

 

ID6

 

codes.

 

Note:

 

unused

 

ID’s

 

should

 

be

 

set

 

as

 

OFF

 

(displayed

 

“OF”

 

on

 

screen).

 

After

 

setting

 

ID6,

 

set

 

the

 

BAUD

 

rate

 

to

 

512

 

Then

 

set

 

the

 

FRE

 

(Frequency)

 

to

 

459.2750

 

When

 

the

 

display

 

shows

 

PROGRAM

 

YES?

 

Press

 

the

         

READ

 

key

 

for

 

Yes

 

or

 

the

           

ESCAPE

 

key

 

for

 

No.

 

 

The

 

display

 

will

 

blank

 

 

the

 

Pager

 

has

 

now

 

returned

 

to

 

normal

 

mode

 

in

 

the

 

off

 

condition.

 

Press

 

and

 

hold

 

the

         

READ

 

key

 

for

 

2

 

seconds

 

 

the

 

Pager

 

will

 

beep

 

4

 

times

 

and

 

display

 

Aid

 

Call

.

 

Perform

 

a

 

test

 

to

 

check

 

the

 

Pager

 

is

 

operating

 

as

 

required.

 

 
 
 

Summary of Contents for Touchsafe Pro J25

Page 1: ...mprovement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support CAL001 Daisy War...

Page 2: ...tup so all calls are reported to all Pagers at all times or day night groups can be set so different Pagers can be alerted depending on the time of day The types of call that are reported to the Pager...

Page 3: ...this manual Do not expose to direct sunlight Do not submerge in water and do not use in damp or humid conditions Do not expose to dripping or splashing water As with any electronic equipment take care...

Page 4: ...d recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTE E 4 MAINTENANCE CARE For peace of mind and to ensure your system is mainta...

Page 5: ...hand corner of the display Press any key to return to the STANDBY SCREEN POWER OFF Press any key to go to the STANDBY SCREEN Press and hold the ESCAPE key for 2 seconds to display the SETTINGS menu U...

Page 6: ...ed in the Pager memory Press any key to go to the STANDBY SCREEN then press the READ key to read stored messages Scroll through the messages using the or keys Note if you scroll to the end of the mess...

Page 7: ...ey should be as listed below V7 1 Software Version SN xxxxxxxx Serial No LCD all display pixels and icons should illuminate VIBRATOR unit should vibrate LAMP LCD backlight LED s should illuminate BEEP...

Page 8: ...d be notified The Touchsafe Pro Nursecall system can be setup with different call types to different Pager ID s on a per zone basis refer to the Astra Transmitter Maxpage Terminal manuals 14 MANUAL PR...