background image

Doc

 

No.

 

FM5615

 

issue

 

A

 

Page

 

7

  

 

10.

 

PAGER

 

SETTINGS

 

MENU

 

 

Press

 

any

 

key

 

to

 

go

 

to

 

the

 

STANDBY

 

SCREEN

.

 

Use

 

the

 

 

or

 

 

keys

 

to

 

select

 

from

 

the

 

following

 

options;

 

Select

 

SET

 

ALERT

 

to

 

choose

 

Tone,

 

Vibrate,

 

Tone

 

&

 

Vibrate

 

or

 

Silent

 

Select

 

TURN

 

OFF

 

to

 

switch

 

the

 

Pager

 

off

 

Select

 

DATE

 

&

 

TIME

 

to

 

set

 

the

 

correct

 

time

 

&

 

date

 

Press

 

the

          

READ

 

key

 

to

 

confirm

 

selection.

 

Use

 

the

 

 

or

 

 

keys

 

to

 

modify

 

the

 

options

 

and

 

press

 

the

         

READ

 

key

 

to

 

enter

 

The

            

ESCAPE

 

key

 

takes

 

you

 

back

 

to

 

the

 

STANDBY

 

SCREEN

 

without

 

saving

 

changes.

 

 
 

11.

 

CHECKING

 

THE

 

PAGER

 

SETTINGS

 

 

Remove

 

the

 

battery

 

from

 

the

 

Pager,

 

press

 

and

 

hold

 

the

           

ESCAPE

 

key

 

and

 

re

insert

 

the

 

battery

 

keeping

 

it

 

pressed

 

until

 

TEST

 

is

 

displayed

 

on

 

the

 

screen,

 

then

 

release.

 

Press

 

the

         

READ

 

key

 

to

 

step

 

through

 

the

 

factory

 

settings;

 

they

 

should

 

be

 

as

 

listed

 

below;

  

 

V7.1

 

(Software

 

Version)

 

SN:

 

xxxxxxxx

 

(Serial

 

No.)

 

LCD

 

 

all

 

display

 

pixels

 

and

 

icons

 

should

 

illuminate

 

VIBRATOR

 

 

unit

 

should

 

vibrate

 

LAMP

 

 

LCD

 

backlight

 

LED’s

 

should

 

illuminate

 

BEEP

 

 

beeper

 

should

 

sound

 

ID1:

 

xxxxxxx,

 

ID2:

 

xxxxxxx,

 

ID3:

 

xxxxxxx,

 

ID4:

 

xxxxxxx,

 

ID5:

 

xxxxxxx,

 

ID6:

 

xxxxxxx

 

(6

 

Site

 

Specific

 

ID’s)

 

BAUD:

 

512

 

RF

 

FREQ:

 

459.2750

 

 

The

 

above

 

will

 

then

 

repeat,

 

press

 

the

           

ESCAPE

 

key

 

to

 

exit.

 

 
 

12.

 

ASTRA/MAXPAGE

 

PAGER

 

ID’s

 

 

If

 

J25

 

Pagers

 

are

 

being

 

used

 

with

 

an

 

Astra

 

Transmitter

 

then

 

first

 

4

 

digits

 

of

 

each

 

ID

 

MUST

 

be

 

0012;

 

the

 

remaining

 

3

 

digits

 

can

 

be

 

any

 

numbers.

 

With

 

a

 

Maxpage

 

Terminal

 

all

 

7

 

digits

 

can

 

be

 

any

 

numbers.

 

 
  
 
 
 
 
 
 
 
 
 
 
 

Each

 

Pager

 

can

 

be

 

programmed

 

with

 

up

 

to

 

6

 

different

 

ID’s,

 

these

 

will

 

normally

 

be

 

assigned

 

as

 

individual

 

codes

 

plus

 

group

 

codes

 

 

see

 

section

 

13.

 

 
 
 
 

Astra

 

Transmitter

 

 

Pager

 

ID’s

 

must

 

start

 

with

 

0012

 

followed

 

by

 

any

 

3

 

numbers

 

e.g.

 

 

ID1:

 

ON

 

0012xxx

 

Maxpage

 

Terminal

 

 

Pager

 

ID’s

 

can

 

be

 

any

 

7

 

digit

 

numbers

 

e.g.

 

 

ID1:

 

ON

 

1234567

 

Summary of Contents for Touchsafe Pro J25

Page 1: ...mprovement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support CAL001 Daisy War...

Page 2: ...tup so all calls are reported to all Pagers at all times or day night groups can be set so different Pagers can be alerted depending on the time of day The types of call that are reported to the Pager...

Page 3: ...this manual Do not expose to direct sunlight Do not submerge in water and do not use in damp or humid conditions Do not expose to dripping or splashing water As with any electronic equipment take care...

Page 4: ...d recycling of batteries Return used batteries to your supplier or drop off at your local municipal waste recycling depot NTE E 4 MAINTENANCE CARE For peace of mind and to ensure your system is mainta...

Page 5: ...hand corner of the display Press any key to return to the STANDBY SCREEN POWER OFF Press any key to go to the STANDBY SCREEN Press and hold the ESCAPE key for 2 seconds to display the SETTINGS menu U...

Page 6: ...ed in the Pager memory Press any key to go to the STANDBY SCREEN then press the READ key to read stored messages Scroll through the messages using the or keys Note if you scroll to the end of the mess...

Page 7: ...ey should be as listed below V7 1 Software Version SN xxxxxxxx Serial No LCD all display pixels and icons should illuminate VIBRATOR unit should vibrate LAMP LCD backlight LED s should illuminate BEEP...

Page 8: ...d be notified The Touchsafe Pro Nursecall system can be setup with different call types to different Pager ID s on a per zone basis refer to the Astra Transmitter Maxpage Terminal manuals 14 MANUAL PR...

Page 9: ...ide the battery cover to the right to remove the battery Used batteries must not be disposed of in domestic waste Do not incinerate or mutilate used batteries the chemicals released are corrosive and...

Page 10: ...kerman and 4 with Maxpage ESPA No of Pagers Site Unlimited No of CAP Codes ID s 6 No 7 digit numeric codes Factory ID1 ON 1234567 Factory ID2 ID5 All OFF 1234567 Programming Manually by hand via LCD O...

Reviews:

Related manuals for Touchsafe Pro J25