background image

9

The  crossed  out  wheelie  bin  symbol  that  is  on  your 
product indicates that this product should not be disposed 
of  via  the  normal  household  waste  stream.  Proper 
disposal will prevent possible harm to the environment or 
to  human  health.  When  disposing  of  this  product  please 
separate it from other waste streams to ensure that it can 
be  recycled  in  an  environmentally  sound  manner.  For 
more  details  on  collection  and  proper  disposal,  please 
contact your local government office or the retailer where 
you purchased this product.

Ei Electronics, Shannon, Co. Clare, Ireland

Nominal activation conditions/ sensitivity,
response delay (response time) and
performance under fire condition

Pass

Operational reliability

Pass

Tolerance to voltage supply

Pass

Response delay and temperature resistance

Pass

Vibration resistance

Pass

Humidity resistance

Pass

Corrosion resistance

Pass

Electrical stability

The Declaration of Performance No. 15-0005 may be consulted
at www.eielectronics.com/compliance

Pass

15

DoP No.15-0005

EN14604:2005 + AC:2008

Smoke Alarm Devices:

Ei161e, Ei166e

Heat Alarm Devices:

Ei164e

Fire Safety

0086

 

Summary of Contents for Ei160e Series

Page 1: ...Rechargeable Battery Backup Ei Electronics 2018 P N B18148 Rev4 Aico Ltd Mile End Business Park Maesbury Rd Oswestry Shropshire SY10 8NN U K Tel 01691 664100 www aico co uk Ei Electronics Shannon Co...

Page 2: ...n decorating to prevent dust or other contamination damaging the unit Clean your Alarm regularly RF Interconnection The Ei160e series is supplied with an Easi Fit base that allows very quick and simpl...

Page 3: ...l the units should alarm within 10 seconds of the first horn sounding The red light on the first unit only will flash about once a second On releasing the button the local Alarm will stop sounding imm...

Page 4: ...returned to the manufacturer for repair or replacement see Service and Guarantee section Cleaning WARNING Electrical shock hazard Disconnect the AC mains at the fuse box or circuit breaker powering th...

Page 5: ...ilenced by disconnecting the mains power and removing the unit see ALARM REMOVAL section page 11 Installer If cleaning the Alarm does not correct the problem it can be returned to the manufacturer for...

Page 6: ...Call the Fire Brigade immediately on a mobile phone or from a neighbour s house Make sure to call the Brigade for all fires no matter how small fires can suddenly spread Also call the Brigade even if...

Page 7: ...e of purchase Ei Electronics guarantees this Alarm for five years from date of purchase against any defects that are due to faulty materials or workmanship This guarantee only applies to normal condit...

Page 8: ...d replace the unit 1 If the green mains light is on and recharging the Lithium cells or cleaning the unit has not stopped the beeps a fault may exist Disconnect the mains first and replace the unit se...

Page 9: ...local government office or the retailer where you purchased this product Ei Electronics Shannon Co Clare Ireland Nominal activation conditions sensitivity response delay response time and performance...

Page 10: ...10...

Page 11: ...GES SLIDE ON ALARM 3 LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM THE SLOT IS LOCATED DIRECTLY ABOVE THE ARROW INSERT A FLAT BLADED SCREWDRIVER HORIZONTALLY APPROX 1cm INTO THE CENTRE OF THE REMOVA...

Page 12: ...false alarms are minimised to ensure the units are not disabled or ignored The BS standard gives guidance on how many Alarms to install what type of Alarm to use where to position Alarms The above po...

Page 13: ...ets or bathroom Minimum Protection LD3 Alarms in all hallways stairways and circulation areas that form part of the escape routes from the dwelling UK Requirements BS 5839 6 2013 Interconnect all Alar...

Page 14: ...and all high fire risk areas rooms e g kitchen living rooms garages and all bedrooms apart from toilets or bathroom Interconnect all Alarms Heat Alarms located in Heat Alarms must be within 5 3m of p...

Page 15: ...In enclosed kitchens with doors closed 5 Greatly depends on ventilation and distance from source of fumes Grade D System The mains powered Smoke and Heat Alarms with battery back up covered by these...

Page 16: ...tom of the detection element is above the level of any door openings Wall mounting should only be considered where close spaced beams or similar obstructions may preclude ceiling mounting It is consid...

Page 17: ...n built in terminal block to connect it to the mains The mounting plate can be screwed directly to the ceiling Alternatively it can be screwed to a standard junction box It requires a current of 40mA...

Page 18: ...s should be connected on a single final circuit unless the means of interconnection is by radio signals e g RadioLINK See BS 5839 6 2013 for further information Note The Ei100MRF RadioLINK Module can...

Page 19: ...are two other positions which are also suitable for the surface wiring to enter and exit the alarm one next to the removable section and another directly opposite 5 Carefully align the mounting plate...

Page 20: ...NG Do not connect these Alarms to any other model produced by another manufacturer Doing so may damage the Alarms and could result in a shock or fire hazard Wiring must be installed in compliance with...