30
NOTICE
When stopping the engine with the touch
switch, push in the emergency stop switch.
After a lapse of 1 second, pull out the
emergency stop switch and the machine
functions will be restored.
Touch switch
M179B22-1
Fig. 6‒4
2‒4 Tilt Warning Check
Set up the machine in the following state:
- Platform load: 1 operator
- Boom elevation: horizontal
- Boom telescope: fully retracted
Make sure the tilt light goes on and alarm
buzzer sounds when the machine tilts more
than 5°
, e.g. by traveling up onto a slope more
than 5°
(within the gradeability).
2‒5 Last Check
Retract the boom fully and lower the boom
fully
Put the machine on a firm, level surface and
turn the key switch to “
” (OFF) to shut down
the engine.
Circle the machine and check visually that there
are no oil leaks.
The pre-operation check is now complete.