50
6. Hydraulic Generator
(If Equipped)
6‒1 To Start the Hydraulic
Generator
Make sure that key switch is in the
“
” (UPPER CONTROLS) position.
Key switch
M179D12-1
Fig. 8‒44
Make sure that engine is running.
NOTICE
Warm the hydraulic oil before operating
the generator. Cold hydraulic oil may
cause generator damage.
Make sure that foot switch is not depressed.
NOTICE
Depressing the foot switch while the
hydraulic generator switch is “ON” disables
the hydraulic generator and enables
operation of the machine.
To start the hydraulic generator,
turn the hydraulic generator switch
to “ON” position.
The hydraulic generator light will go on when
the hydraulic generator switch is turned on.
Hydraulic Generator Light
Hydraulic Generator Switch
M179E32-1
Fig. 8‒45
6‒2 To Restore Normal Operation
To turn off the hydraulic generator, operate the
hydraulic generator switch down to its “OFF”
position.
The hydraulic generator light will go off when
the hydraulic generator switch is turned off.
NOTICE
• An engine shut down will turn the
hydraulic generator off.
• Depressing the foot switch while the
hydraulic generator switch is “ON” disables
the hydraulic generator and enables
operation of the machine.
DANGER
Do not plug devices that need continuous
electricity into generator such as electro-
lifting magnet.