6 External output
This turbine meter is equipped with two open-drain outputs
*1
.
To extract the outputs, use the dedicated external connection cable with a plug.
Standard specifications
Model TBX30(D)
TBX100(D)
TBX100F(D)
TBX150F(D)
Unit pulse
Pulse output unit
10L/P
100L/P
Pulse output width
40ms
Maximum ON current
20mA
Maximum ON
resistance
*2
50
Ω
Maximum frequency
*3
Approx. 0.8 Hz
Approx. 2.8 Hz
Approx. 0.4 Hz
High-density
pulse
Pulse output unit
Approx. 110
cm
3
/p
Approx. 250 cm
3
/p
Approx. 470
cm
3
/p
Minimum pulse output
width
Approx. 13 ms
Approx. 9 ms
Approx. 11 ms
Maximum ON current
10 mA
Maximum ON
resistance
*2
100
Ω
Maximum frequency
Approx. 75 Hz
Approx. 110 Hz
Approx. 90 Hz
Maximum applied voltage
24 VDC
*1 Unit pulse: A flow rate pulse after the unit matching by an arithmetic circuit
High-density pulse: A flow rate pulse that is output in synchronization with the rotation of the impeller
Duty ratio: 0.45 to 0.55 (at a constant flow rate)
*2 The OFF resistant is 100 k
Ω
or more.
*3 The maximum frequency with the standard specifications. The maximum frequency varies with the
pulse output unit that has been set.
Note that the maximum frequency will be approximately 8 Hz when the pulse output unit of TBX30 (D)
is set to 1 L/P.