2    Precautions for use 

 

 

Caution

 

1.    Do not install the product at a dangerous place.

 

 

Do Not

 

Do not use the product for applications to which a high level of safety is required, 
such as nuclear power, railway, aviation, vehicle, and amusement applications.   
The electric circuits in this turbine meter do not have an anti-explosion structure. 

2.    Do not use this product for the measurement of corrosive gases or 

the gases listed below.

 

 

Do Not

 

It may corrode parts in use or cause a leakage of gas. In addition, the 
measurements can be inaccurate. 

 

Chlorine, hydrogen cyanide, nitrogen dioxide, fluorine

 

Toxic gases

 

Hydrogen chloride, boron trifluoride, boron dioxide

 

 

Sulfur dioxide, hydrogen fluoride, hydrogen sulfide 

Others

 

Ammonia, chlorine dioxide, oxygen, hydrogen, helium 

Depending on the property of the gas to be measured, the meter may become 
deteriorated in performance or damaged. Contact us before measuring a special 
gas. 

3. 

Do not give an impact to the meter. 

 

Do Not

 

 

The meter is a precision measuring 
instrument. Do not give a strong impact to 
the meter or hit the meter with an object. 
Besides, do not insert a cylindrical object 
into the meter. It may cause a leakage of 
gas or damage. 

4.    Do not disassemble the meter. 

 

Do not 

disassemble

 

The meter is a precision measuring 
instrument. Do not disassemble it. It may 
cause a leakage of gas. 

5.    Conduct an airtightness test to the installed meter, including the 

pipes located prior and subsequent to it. 

 

Do

 

Check that no leakage occurs at a 
pressure 1.1 times larger than the 
maximum allowable working pressure. 

6.    Connection to an external power source (applicable for the external 

power source type) 

 

Do

 

Use caution not to make a short circuit when connecting the external connection 
cable to a power source.   
The power source used should be an isolation type having a short-circuit protection 
function. 

 

Conduct an airtightness test 

between these points.

Strainer

 

Meter

Summary of Contents for TBX100

Page 1: ...wer Source Type TBX30D TBX100D TBX100FD TBX150FD Thank you for purchasing this product Please read through this instruction manual carefully and use the product properly The warranty is on the back co...

Page 2: ...proper use of the turbine gas meter for management and control this instruction manual contains various pictograms intended to prevent injuries to you and other people or damage to property Those pic...

Page 3: ...rformance or damaged Contact us before measuring a special gas 3 Do not give an impact to the meter Do Not The meter is a precision measuring instrument Do not give a strong impact to the meter or hit...

Page 4: ...Do 2 The orientation markings on the main body of the meter must be the same as the direction of the gas flow Do 3 Straight pipes having a length of 10D i e 10 times the pipe diameter or greater must...

Page 5: ...nuts softly before tighten them in an even crisscross pattern applicable for TBX100F D and TBX150F D Tightening torque 100 N m max Secure the minimum design fastening pressure recommended by the gask...

Page 6: ...your nearest branch office or sales office Name or model Appearance Quantity Remarks Built in battery type External power source type Standard items Turbine meter main body 1 For the model name refer...

Page 7: ...urce type L Left inlet left to right R Right inlet right to left U Bottom inlet bottom to top D Top inlet top to bottom 3 32A Rc 11 4 4 40A Rc 11 2 Integrated flow rate display Instantaneous flow rate...

Page 8: ...4 Rc 1 1 2 Rc 2 JIS 10K Flange 50A Operating temperature range C 10 to 60 Installation angle Horizontal and vertical Measurable gas 1 City gas 2 LP gas 2 air nitrogen Power source Built in battery ty...

Page 9: ...e output width Approx 13 ms Approx 9 ms Approx 11 ms Maximum ON current 10 mA Maximum ON resistance 2 100 Maximum frequency Approx 75 Hz Approx 110 Hz Approx 90 Hz Maximum applied voltage 24 VDC 1 Uni...

Page 10: ...ironments approx 60 C The battery cannot be replaced 1 Applicable only for Built in battery type products When the remaining battery life becomes less than about one month a running down battery alarm...

Page 11: ...only used Terminal box For indoor communication wires 4 terminals 2 External power source type External connection cable Use the dedicated external connection cable to supply a 12 to 24 VDC power and...

Page 12: ...Description Red Black White Blue Yellow Green Power supply 12 to 24 VDC Power GND Unit pulse Unit pulse High density pulse High density pulse Terminal box optional The terminal box is used when the ex...

Page 13: ...er 8 Use caution not to let foreign objects such as weld tips foreign objects and sealant enter during the installation of pipes 9 Do not install this turbine meter at a place where it is subjected to...

Page 14: ...Rotate the counter 180 degrees C Rotate the mounting plate 90 degrees to secure it Use the attached screws 3 Secure the counter again The display can have an angle up to approximately 10 degrees A Rem...

Page 15: ...value Pressing and holding the switch continuously for three seconds or longer will change the display to an integrated flow rate value Instantaneous flow rate switch Trip flow rate switch While an in...

Page 16: ...as not been completed the constant data to be used is the previous setting value The following figure shows the flow of constant setting and display Constant display mode Press and hold the FLOW RATE...

Page 17: ...letion of setting to confirm the setting value and then the display will return to the item selection current setting value display The following figure shows the overview of setting flow Press the FL...

Page 18: ...output width between 40 and 120 1 Press the FLOW RATE switch Press and hold the FLOW RATE switch for two seconds confirmation of setting 5 Pulse output width setting current setting value display Pres...

Page 19: ...etection of the power failure is restored and the integration is resumed from that value The product has the inventory mode for reducing the power consumption while it is in stock In the inventory mod...

Page 20: ...he pilot does not blink in spite of the presence of a gas flow detach the meter from the pipes and then gently blow air into the inlet of the meter to check whether or not the pilot on the indicator b...

Page 21: ...t in battery type 4 wires External power source type 6 wires Terminal box optional Extension wire 200 m max Use a steel conduit tube as an anti noise measure Built in battery type External connection...

Page 22: ...ate m3 h Instantaneous flow rate m3 h Pressure loss Pa Pressure loss Pa Pressure loss Pa Instrumental error Instrumental error Turbine meter TBX100 D TBX100F D general performance diagram low pressure...

Page 23: ...The most significant digit of the integrated flow rate display is blinking The voltage of the battery has reduced applicable only for the Built in battery type The blink indicates that the battery is...

Page 24: ...damage due to a human made disaster flood damage earthquake lightening or other natural disaster pollution or abnormal voltage 4 Lack of presentation of this warranty 5 Malfunction or damage due to t...

Reviews: