Aichi Tokei Denki TBX100 Instruction Manual Download Page 24

 
 
 

 

 

Warranty of the turbine gas meter for management and control 

Base model names:   TBX30, TBX100, TBX100F, TBX150F, TBX30D, TBX100D, TBX100FD, 

TBX150FD 

This product has been delivered through strict quality control and close inspection. This warranty is 
to assure that this product will be replaced at no charge on the basis of the conditions described in 
this warranty, in the event that this product goes out of order under the customer's normal use 
conditions.  

Note 

1.    The warranty period is one year from the date of purchase, and the warranty covers only the 

main body. In the event that a failure occurs during the warranty period, contact us presenting 
this warranty.   

2.    This warranty will not be reissued. Retain it in a safe place.   
3.    Refer to the following for the provisions of this warranty. 

Provisions for free-of-charge replacement 

1.    Aichi Tokei Denki will replace the product at no charge in the event that it goes out of order 

within one year under normal use conditions in accordance with the directions in the instruction 
manual.  

2.    This warranty must be presented when you have the product that has gone out of order within 

the warranty period replaced at no charge.   

3.    Even in the warranty period, the following cases will not be covered by the warranty.   

1)    Malfunction or damage due to an error in use or an illegal adaption 
2)    Malfunction or damage due to the relocation of the mounting position, impact, or falling 

after the purchase   

3)    Malfunction or damage due to a human-made disaster; flood damage, earthquake, 

lightening, or other natural disaster; pollution, or abnormal voltage 

4)    Lack of presentation of this warranty 
5)    Malfunction or damage due to the use of a gas out of specification 

4.    This warranty is valid only in Japan. 

 

Date of purchase 

___ / __ 

Name of the customer 

 

Address  

Fill in the columns based 
on the nameplate. 

Model  

Serial  

Name of the gas used 

 

 
Dear customer,   
Please fill in the date of purchase, name, address, model, serial number, and name of the gas used 
when you receive this warranty.   
 

  Aichi tokei denki co., ltd.

 

1-2-70 Chitose, Atsuta-ku, Nagoya, 456-8691, JAPAN 

URL:http://www.aichitokei.co.jp

 

 

 

 

Contact us at your nearest branch office or business office. 

 

Sapporo Branch Office  TEL (011)642-9500 
Kushiro Sales Office 

TEL (0154)23-7859 

Sendai Branch Office 

TEL (022)258-1181 

Aomori Sales Office 

TEL (017)742-6771 

Morioka Sales Office 

TEL (019)646-8836 

Tokyo Branch Office 

TEL (03)3209-0631 

Yokohama Sales Office  TEL (045)661-1491 
Chiba Sales Office 

TEL (03)5658-1320 

Omiya Sales Office 

TEL (048)668-0131 

Niigata Satellite Office  TEL (025)282-5591 

Nagoya Branch Office

TEL (052)661-5852

Kanazawa Sales Office  TEL (076)252-1942 
Shizuoka Sales Office 

TEL (054)237-7168 

Nagano Satellite Office  TEL (026)254-5677 
Osaka Branch Office 

TEL (06)6305-9052 

Hiroshima Sales Office 

TEL (082)292-8289 

Takamatsu Sales Office  TEL (087)851-6664 
Okayama Sales Office 

TEL (086)207-6828 

Fukuoka Branch Office 

TEL (092)534-2050 

Kagoshima Sales Office  TEL (099)254-7877 

Miyazaki Satellite Office TEL 

(0985)24-2279

Okinawa Satellite Office TEL 

(098)860-9792

Overseas Sales Headquarters TEL (052)661-5150
 

 

 

Preservation 

bag

 

Revised

18.04

Summary of Contents for TBX100

Page 1: ...wer Source Type TBX30D TBX100D TBX100FD TBX150FD Thank you for purchasing this product Please read through this instruction manual carefully and use the product properly The warranty is on the back co...

Page 2: ...proper use of the turbine gas meter for management and control this instruction manual contains various pictograms intended to prevent injuries to you and other people or damage to property Those pic...

Page 3: ...rformance or damaged Contact us before measuring a special gas 3 Do not give an impact to the meter Do Not The meter is a precision measuring instrument Do not give a strong impact to the meter or hit...

Page 4: ...Do 2 The orientation markings on the main body of the meter must be the same as the direction of the gas flow Do 3 Straight pipes having a length of 10D i e 10 times the pipe diameter or greater must...

Page 5: ...nuts softly before tighten them in an even crisscross pattern applicable for TBX100F D and TBX150F D Tightening torque 100 N m max Secure the minimum design fastening pressure recommended by the gask...

Page 6: ...your nearest branch office or sales office Name or model Appearance Quantity Remarks Built in battery type External power source type Standard items Turbine meter main body 1 For the model name refer...

Page 7: ...urce type L Left inlet left to right R Right inlet right to left U Bottom inlet bottom to top D Top inlet top to bottom 3 32A Rc 11 4 4 40A Rc 11 2 Integrated flow rate display Instantaneous flow rate...

Page 8: ...4 Rc 1 1 2 Rc 2 JIS 10K Flange 50A Operating temperature range C 10 to 60 Installation angle Horizontal and vertical Measurable gas 1 City gas 2 LP gas 2 air nitrogen Power source Built in battery ty...

Page 9: ...e output width Approx 13 ms Approx 9 ms Approx 11 ms Maximum ON current 10 mA Maximum ON resistance 2 100 Maximum frequency Approx 75 Hz Approx 110 Hz Approx 90 Hz Maximum applied voltage 24 VDC 1 Uni...

Page 10: ...ironments approx 60 C The battery cannot be replaced 1 Applicable only for Built in battery type products When the remaining battery life becomes less than about one month a running down battery alarm...

Page 11: ...only used Terminal box For indoor communication wires 4 terminals 2 External power source type External connection cable Use the dedicated external connection cable to supply a 12 to 24 VDC power and...

Page 12: ...Description Red Black White Blue Yellow Green Power supply 12 to 24 VDC Power GND Unit pulse Unit pulse High density pulse High density pulse Terminal box optional The terminal box is used when the ex...

Page 13: ...er 8 Use caution not to let foreign objects such as weld tips foreign objects and sealant enter during the installation of pipes 9 Do not install this turbine meter at a place where it is subjected to...

Page 14: ...Rotate the counter 180 degrees C Rotate the mounting plate 90 degrees to secure it Use the attached screws 3 Secure the counter again The display can have an angle up to approximately 10 degrees A Rem...

Page 15: ...value Pressing and holding the switch continuously for three seconds or longer will change the display to an integrated flow rate value Instantaneous flow rate switch Trip flow rate switch While an in...

Page 16: ...as not been completed the constant data to be used is the previous setting value The following figure shows the flow of constant setting and display Constant display mode Press and hold the FLOW RATE...

Page 17: ...letion of setting to confirm the setting value and then the display will return to the item selection current setting value display The following figure shows the overview of setting flow Press the FL...

Page 18: ...output width between 40 and 120 1 Press the FLOW RATE switch Press and hold the FLOW RATE switch for two seconds confirmation of setting 5 Pulse output width setting current setting value display Pres...

Page 19: ...etection of the power failure is restored and the integration is resumed from that value The product has the inventory mode for reducing the power consumption while it is in stock In the inventory mod...

Page 20: ...he pilot does not blink in spite of the presence of a gas flow detach the meter from the pipes and then gently blow air into the inlet of the meter to check whether or not the pilot on the indicator b...

Page 21: ...t in battery type 4 wires External power source type 6 wires Terminal box optional Extension wire 200 m max Use a steel conduit tube as an anti noise measure Built in battery type External connection...

Page 22: ...ate m3 h Instantaneous flow rate m3 h Pressure loss Pa Pressure loss Pa Pressure loss Pa Instrumental error Instrumental error Turbine meter TBX100 D TBX100F D general performance diagram low pressure...

Page 23: ...The most significant digit of the integrated flow rate display is blinking The voltage of the battery has reduced applicable only for the Built in battery type The blink indicates that the battery is...

Page 24: ...damage due to a human made disaster flood damage earthquake lightening or other natural disaster pollution or abnormal voltage 4 Lack of presentation of this warranty 5 Malfunction or damage due to t...

Reviews: