www.ahs-antriebstechnik.de
Technische Änderungen vorbehalten /
Specifications are subject to change without notice
AN-01-EN-6410-BA.doc
Step motor drive TSP10-BA
Page 6 of 13
TSP10
For the switch position S1 = 0, the motor current is a preset value. This value can be modified
and saved in the TSP10-BA with the set-up program "TopSuite".
Values range: 200 ... 7000 mA
rms
Step resolution / Idle current reduction
With the rotary switch for the step resolution (S2), also the delay time for the current reduction
is set. The motor current is reduced to 50% after the delay time expires (position 0...7).
No current reduction is done for the switch positions 8 to F.
S2 Position 0 ... 7 idle time = 0.1 Second, Idle Current Reduction to 50 %
S2 Position 8 ... F no current reduction
6410
TSP10-BA
Revolutions per
steps
DIP1
DIP2
DIP3
J 3-4
Switch S2 Position
with SSR
without
SSR
1/1
(200/full step)
close
close
close
set
1
9
1/2
(400/Half
step)
close
close
close
open
2
A
1/2
(400/Halfstep)
close
close
open
set
2
A
1/2,5
(500)
---
---
---
---
3
B
1/4
(800)
close
close
open
open
4
C
1/5
(1000)
close
open
close
set
5
D
1/8
(1600)
close
open
close
open
---
---
1/10
(2000)
close
open
open
set
6
E
1/16
(3200)
close
open
open
open
---
---
1/25
(5000)
open
close
close
set
7
F
1/32
(6400)
open
close
close
open
---
---
1/50
(10000)
open
close
open
set
0*
8
1/64
(12800)
open
close
open
open
---
---
1/125
(25000)
open
open
close
set
---
---
1/128
(25600)
open
open
close
open
---
---
1/250
(50000)
open
open
open
set
---
---
1/256
(51200)
open
open
open
open
---
---
*
Switch S2 to Position 0 = factory set-up